KAMCONSUUANTS 35-40 36th Street Long Island City New York, 11106 Tel: (718)729-1307 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# 28A 28B 28C 29A 29B Lab Sample ID^ 010905B-220 010905B-221 010905B-222 010905B-223 010905B-224 Sample Location Roof'B" Roof"B" Roof'B" Roof'B" Roof'B"

Homogeneity Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof Membrane Roof Membrane Roof Membrane Roof Membrane 1st Laver 2nd Laver 3rd Laver I.st Laver 2nd Laver

Color Blk Blue Blk Blk Blue Texture Fibrous Non Fibrous Mixed Fibrous Non Fibrous Sample Treatment. None Acid Digestion Acid Digestion None Acid Digestion & Ashing & Ashing & Ashing Asbestos Present (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent)- 90%FBGL 0% 40%FBGL 95%FBGL 0% Non Fibr Mat (Percent). 10% 100% 60% 5% 100% Date Received; 9/5/01 Date of Analysis- 9/6/01 Date of Report: 9/7/01

Analyst: ■ 01 Lab Manager 1 M. Ulanecki ♦ Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing ♦ Samples will be stored for ninety (90) days and then returned to the client upon request ♦ The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NVLAP # 102047 AIHA #: 100269

13

NYC-WTC_000386158

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386158Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →