NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA review of samples from 125 Cedar; discussion of asbestos and other chemicals.
NYC-WTC_000369034–000369036OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document I-'. 04/05
relative potency compared to benzo[a]p>TCnc, which is the most toxic of the PAHs. The TEF procedure generally uses ’/j of the detection limit in the calculations when the reported value is below the detection limit. As the results from 125 Cedar Street were all non-detecl, the TEF calculations yield a value of 580 gg/m’ when calculated using 14 the detection limit. The PAH data set would have been more robust had the detection limit been set at 2.5 gg. If a detection limit of 2.5 gg would have been used, the TEF calculations would have yielded a value of 290 gg-W, assuming that the samples remained as non-detect. This distinction is important because the numeric criteria presented in the COPC document is 300 gg/m^ bl an attempt to make an informed evaluation of the PAH data from 125 Cedar Street, a comparison was made to PAH data which USEPA collected from 110 Liberty Street. The PAH data from 110 Liberty indicated that the concentration of the seven PAHs used in the TEF calculations were primarily non detect at a detection limit of 2.5 gg. This indicates that even if a lower detection limit was used at 125 Cedar Street, the results would likely indicate non-detect for the PAHs, similar to what was observed at 110 Liberty Street. In addition, some of the PAHs that are not included in the calculation of TEFs (i.e., non-carcinogenic PAI-Is) were the most frequently detected PAHs at 110 Liberty and were detected at concentrations above 5 gg. The non-carcinogenic PAHs are not included in the TEF calculations because they arc less toxic than the carcinogenic PAHs, dierefore identification of a non-carcinogenic PAH would not increase the TEF value. Thus, it would be expected that some of the non-carcinogenic PAHs would have been detected above 5 ns if they were present at 125 Cedar Street. The combination of these two factors provides evidence that the data collected at 125 Cedar Street can be accepted even though the detection limit was not as low as it could have been, bi addition, the prc-cleaning PAH results are similar to the results observed at 110 Liberty Street. The post-cleaning PAH samples at 110 Liberty Street were all below the numeric criteria as well. Tlierefore, even though the post-cleaning samples from 125 Cedar Street were not evaluated, it is expected that the samples will all be below the numeric criteria based on the pre-cleaning samples being below the criteria and the similarity to what was observed at 110 Liberty Street. Thus, for PAHs, the data we reviewed indicates that PAHs arc not a hazard at 125 Cedar Street.
Dioxin - The analytical data for dioxin that was reviewed consisted only of pre-cleaning samples. Post cleaning samples were also collected, however the analytical results are not available at this date. When the analysis is completed for the post-cleaning samples, USEP.A will review the data. Wc reviewed 66 wipe results which were analyzed for dioxin. Evaluation of dioxin results is similar to that reported above for PAHs in that the results for individual congener groups arc adjusted and summed to provide toxic equivalency for 2,3,7,8-TCDD, the most toxic dioxin congener, using a process called toxic equivalents (TEQs). Similar to the PAH data the TEQ calculations use 14 of the detection limit in the TEQ calculations. The detection limit was acceptable and all of the samples met the numeric criteria of 4 ng/m\ The pre-cleaning dioxin results are similar to the results observed at 110 Liberty Street. The post cleaning dioxin samples at 110 Liberty Street were all below the numeric criteria as well. Tlierefore, even though the post-cleaning samples from 125 Cedar Street were not evaluated, it is expected that the samples will all be below the numeric criteria based on the pre-cleaning samples being below the criteria and the similarity to wbat was observed at 110 Liberty Street. Thus, for dioxin, the data we reviewed indicates that dioxin is not a hazard at 125 Cedar Street.
Lead - Wc reviewed approximately 72 wipe sample results which were analyzed for lead. There were 10 samples that were above the numeric criteria, of 25 gg/ft’, listed in the COPC document. The apartments which exceeded the numeric criteria were 12N, 1 IN. IOS, ION, 9N, 8S, 8N, 3S, and 2S. These apartments were recleaned and retested (14 samples). Six units met the numeric criteria, however three units (12N, 1 IN, and 1 OS) did not meet the numeric criteria. These three units were recleaned and retested. Apartment 12N and lOS met die numeric criteria after the second cleaning. Apartment 1 IN did not meet the numeric criteria and required a third cleaning. The results for apartment 1 IN after the third cleaning were below the numeric criteria. Thus, for lead, the data wc reviewed indicates that lead is not a hazard at 125 Cedar Street.
CITY_21MC100_002863009
NYC-WTC_000369035
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265566
EPA COPC-based evaluation of six chemicals and contaminants post-cleaning.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156067
Letter from EPA Region II summarizing the review of asbestos, PAHs, dioxin, lead, mercury, fibrous glass, and silica test results for 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107523
Letter from EPA Region II summarizing the evaluation of analytical data for various contaminants at 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107518
Letter confirming that DEP has completed cleanup activities at 125 Cedar Street in accordance with contract specifications.
12 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156088
Letter from the NYC Department of Environmental Protection confirming that all clean-up activities at 125 Cedar Street were completed according to contract specifications.
12 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107277
Transmission journal record confirming receipt of asbestos and lead analysis data on November 14, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151524
EPA Region II letter confirming that primary and secondary clearance levels for asbestos and other contaminants were met at 114 Liberty Street.
7 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154940
EPA confirms that primary and secondary clearance levels for contaminants at 114 Liberty Street have been met.
7 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000156067
Letter from EPA Region II summarizing the review of asbestos, PAHs, dioxin, lead, mercury, fibrous glass, and silica test results for 125 Cedar Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107523
Letter from EPA Region II summarizing the evaluation of analytical data for various contaminants at 125 Cedar Street.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107277
Transmission journal record confirming receipt of asbestos and lead analysis data on November 14, 2002.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
Similar indexed content
NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
Similar indexed content
NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
Similar indexed content
NYC-WTC_000265566
EPA COPC-based evaluation of six chemicals and contaminants post-cleaning.
Similar indexed content
NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
Similar indexed content