NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA review of samples from 125 Cedar; discussion of asbestos and other chemicals.
NYC-WTC_000369034–000369036OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Fibrous glass - Wc rcx'iewed approximately 120 PCM results reported as fibrous glass analysis. The highest detected concentration was 0.009 fee, which is below the numeric criteria of 0.01 fZee in the COPC document. Thus, for fibrous glass, the data we reviewed indicates that fibrous glass is not a hazard at 125 Cedar Street.
Mercurj' - Wc reviewed 66 wipe results which were analyzed for mercury. Seventeen samples were below the detection limit of 0.000478 and the highest detected concentration was 0.0164 The COPC document docsnot establish a numeric criteria for mercury, however since USEPA is collecting 250 wipe samples for mercurj’ as part of residential cleanup program a numeric criteria is currently being developed. The draft value, which is subject to revision based upon further evaluation of exposure parameters, is currently 94 Comparison of the mercury concentrations detected to the draft numeric criteria of 94 indicates that mercury is three orders of magnitude below the draft numeric criteria. Thus, for mercury, the data we reviewed indicates that mercury is not a hazard at 125 Cedar Street
Silica - We reviewed the data for 19 air samples which were analyzed for silica (i.e., total quartz). All of the samples were below the detection limit of 10 (1^. The numeric criterion that USEPA has proposed in the COPC document is 1 /xg/m^ Although the COPC document has chosen the value of 1 gg/m , the available methodology for collecting indoor air samples for silica cannot achieve a value this low, therefore a result that is below' the detection limit is considered to be protective of public health. This is the same approach we are using at 110 Liberty Street, where the detection limit was 4 gg. Thus, for silica, the data we reviewed indicates that silica is not a hazard at 125 Cedar Street.
TOTAL P.05
CITY_21MC100_002863010
NYC-WTC_000369036
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265566
EPA COPC-based evaluation of six chemicals and contaminants post-cleaning.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156067
Letter from EPA Region II summarizing the review of asbestos, PAHs, dioxin, lead, mercury, fibrous glass, and silica test results for 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107523
Letter from EPA Region II summarizing the evaluation of analytical data for various contaminants at 125 Cedar Street.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107518
Letter confirming that DEP has completed cleanup activities at 125 Cedar Street in accordance with contract specifications.
12 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156088
Letter from the NYC Department of Environmental Protection confirming that all clean-up activities at 125 Cedar Street were completed according to contract specifications.
12 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107277
Transmission journal record confirming receipt of asbestos and lead analysis data on November 14, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151524
EPA Region II letter confirming that primary and secondary clearance levels for asbestos and other contaminants were met at 114 Liberty Street.
7 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154940
EPA confirms that primary and secondary clearance levels for contaminants at 114 Liberty Street have been met.
7 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156067
Letter from EPA Region II summarizing the review of asbestos, PAHs, dioxin, lead, mercury, fibrous glass, and silica test results for 125 Cedar Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107523
Letter from EPA Region II summarizing the evaluation of analytical data for various contaminants at 125 Cedar Street.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000362726
Summary of analytical results for COPC-related samples; pre/post-cleaning results for WTC area.
Similar indexed content
NYC-WTC_000209419
Summary of analytical results for chemicals including asbestos and dioxin at 125 Cedar Street to evaluate cleaning criteria.
Similar indexed content
NYC-WTC_000369031
EPA COPC summary: pre/post-cleaning results; some areas exceeded numeric criteria.
Similar indexed content
NYC-WTC_000265566
EPA COPC-based evaluation of six chemicals and contaminants post-cleaning.
Similar indexed content
NYC-WTC_000156056
Letter from EPA Region 2 confirming that analytical data for asbestos and other contaminants met numeric criteria for the pilot program.
Similar indexed content