NYC 9/11 Public Portal Document

NOV.15.2001 5:46PM JLC ENVIRONMENTAL NO.752 P.13/14 JLC environmental consultants, INC. 200 Par* Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-0119 Fax: (212) 420-6092 Project No.: 01-2200 Milford Management Corp. ELAP Lab Code: 11020 Analyte. ASBESTOS 20 West 64th Street NIOSH and AIHa Lab Code; 100273 Date Received: 11/15/01 New York, NY 10023 NVLAP Lab Code; 101963 Date Analyzed: 11/15/01 SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0111B439

Site: 99 Battery Place, Naw York, NY

SAMPLE It DATE Aseesras total % of DESCRIPTION/LOCATION COLOR DETECTED? ASBESTOS CONSTITUENTS COLLECTED labh CLIENTS SAMPLE#

030 Roof/ Main Roof/ North Side/ Sample of BLACK NO 0% CELL 10% 11/14/01 Roof Debris Dark FBGL 10% 12841 NTFIB 80% 030F 031 Roof/ Main Roof/ East Side/ Sample of BLACK NO 0% CELL 10% 11/14/01 Roof Debris Dark FBGL 15% 12842 NFIB 75% 031F 032 Roof/ Main Roof/ West Side/ Sample of BLACK NO 0% CELL 12% 11/14/01 Roof Debris Dark FBGL 20% 12843 NFIB 68%

032F 033 Roof/ Water Tower Roof/ West Side/ BLACK NO 0% CELL 16% 11/14/01 Sample of Roof Debris Dark FBGL 20% 12844 NFip 64% 033F

■INSUFRCIENT MATERIAL SUBMITTED "HEM RECOMMENDED •^OT ANALYZED POSITIVE STOP

Sample Anilyglg bv: ASBESTOS CONSTTTUFNTS NON-ASBESTOS CONSTTnJENTS Polsrlsed Light Microscopy-Dispersion Staining (PLM-DS) CHRY « Chiysollla Asbestos PAPF = Paper Fiber AMOS = A(noal(e Aabsstoa MINW= Mineral Wool Msthod of Ssmole PrenafaTfon and Anafyslg; CROC ■ CrocMollta Asbestos FBGL = Rberglaas ACTN B Actlnollta AstBStoe SYNF = Syr(thellcF)bera All samplaa were prepared and analyzed |n accordance w|th the EPA TREM = Trsnioflts Asbaslos CELL = Calluloaa "Method tar the Determination of Asbestos In Bulk Building Materials" ANTH = Anthophyllte Asbestos NAB = Nort-Flbrnua USEPA/ 600/ R-93/116, July 1093. QRGM = Organic Material WOLL = WollaatonllB Inatnimetwailon: HSHR = Horse Hair OTHR = Other Olympus PLM. Model 0H-2.VM Stareomlcroacope, Model ---- ' VM2 1x-4x Gulam Machhiwgla Laboratory Director

Analytical rasulla reflect the make up of the rjialerlBla only In the areas sprppled. Thia "Summary of Analytical Rosulta" shall not be reproduced except In full, without the written approval of JLC Laboratory, and It must pot ba used by client to o(alm product endoraement by NVLAP or any agency of the U.S. Government This mathod la r»t applicable to aemples containing large amounti of fine fibers below the resolution of tha light microscope. The value of Ihls maihod la limited to the quandlailut tdepupcaljon of asbaatoa and the sami'<,uBnl|iaiivo determination of aabeetoa content of bulk sarnploa, sapreaaad as a percintas* of th# protected area. Quantitation of asbestos content was determined with a vlaual volume ertrpite, a caPbrated visual area estgrrtate, and'or point counting procedure, CAUTION; Other fibers with opneil propertiM similar to aabeatos may give positive mferfetences and win ba considered aebestos under this ipathodology. Also, PLM is not conslstenily reliable In detecting asbestos in ffoor coverings and BlmHar non-filable organlcBlIybound materials. Quantitative transmission electron microscopy Is currently the only method that can be used to determine if this matadsl can be conaldeted or treated as non-asbeetos containing.

Page 1 of 2

11/15/01 THU 18:47 [TI/RI NO 5391] CITY_21MC1OO_OO285O476

NYC-WTC_000367031

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →