NYC 9/11 Public Portal Document
NOV.15.20-01 5:42PM JLC ENVIRONMENTAL NO.752 P.5/14
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone; (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2200
Milford Management Corp. ELAP Lab Code: 11029
Analyte: ASBESTOS
20 West 64th Street NIOSH and AIHA Lab Code: 100273 Dote Received: 11/15/01
New York, NY 10023 NVLAP Lab Code: 101953
Rate Analyzed: 11(15(01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch 01118439
Site: 200 Rector Street, New York, NY
SAMPLE #
ASBESTOS TOTAL % OF
DATE DESCRIPTION/ LOCATION COLOR CONSTITUENTS
COLLECTED DETECTED? ASBESTOS
LA R #
CLIENT'S SAMPLE #
005 Roof/ Main Roof/ Center Area/ Sample of BLACK NO 0% NFIB 100%
11114/01 Roof Debris Black
12813
005A
006 Roof/ 10th Floor Roof/ West Side/ Sample TAN YES 1.1% CHRY 1.1%
11114/01 of Roof Debris Tan CELL 10.9%
12814 FBGL 40%
NFIB 48%
0068
007 Roof! 10th Floor Roof/ East Side/ Sample TAN TRACE <1% ANTH <1%
11/14/01 CELL 10%
of Roof Debris Tan
12815 FBGL 40%
NFIB 50%
007E
008 Roof/ 10th Floor Roof/ South East Side/ TAN TRACE <1% CHRY <1%
11/14/01 Sample of Roof Debris Tan CELL 12%
12816 FBGL 35%
NFIB 53%
008B
INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED "NOT ANALYZED POSITIVE STOP
Semple Analysts bX ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dleperelon Staining (PLM-DS) GARY = Chrysogle Asbestos PAPF = Paper Fiber
AMOS = Arnosits Aabeetoe MiNW = Mineral Wool
CROC = Crocldolhe Asbestos FBGL = Fit~lesa
Method of Semole Pjeaera0on an Analysis:
AGETd = Tracnolte Asbestos llulose Fibers
YNF = Synthetic
CELL
All samPlea wereprepared and analyzed
Y'z 1p ec~rdepca with the EPA TRE.M = Tremolite Asbestos CELL = Cellulose
"Method for the Retefminatlon of Asbestos in Bulk By~iiding Materials" ANTH = Anthophyllie Asbestos NFIB = Non-F1 xotte
USEPA/ 600/ R-03/116, July 1993. ORGM = Organic Materiel
WOLL = Woilastonita
Ina imenrfLen- HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model DH-2NM Stereomlcroscope. Model ^- `^ •I-' ^ --- -
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make tip of the materials only in the areas sampled, Thla "Summary of Analytial Results' shall not be reproduced except In full, without the written
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agertey of tip U.S. Government This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the Iight microscope. The value of this method Is limited to the quandtagve Identification of asbestos
and the semlquanthattve determination of asbestos content of bxrtk samples, expressed as a percentage of pie protected area. Auandtatlon of asbestos content was
determined with a visual volynme eadgfate, a calibrated vlsyal area estimate, and/or point counting proadpre. CAUTION: Other fibers with optical properties similar to asbestos
may give positive Interferwices and will be considered asbestos under this methodology. Also, PLM Is r at consletently reliable In detecting asbestos In floor caavarfngs and
elmrtilar nor-Mable organicafy-bound materials, Quantitative transmission electron microscopy is currently the only method that can be used to determine If this material can be
considered or treated as non-esbeatoa containing.
Page 2 of 4
11/15/01 THU 18:47 [TX/RX NO 5391]
NYC-WTC_ 000120709