NYC 9/11 Public Portal Document
Parc Place (225 Rector Place): Tested 9/23-28/01, 10/31, 11/15-16, 11/28/01
1. One hundred twenty five ambient air samples for asbestos were
collected from 9/23-28/01 and analyzed by PCM. All areas samples
recorded fiber levels less than or equal to 0.01f/cc.
2. Eighty-two ambient air samples for asbestos were collected 10/31,
11/15-16, 11/28/01and analyzed byTEM. The results indicated that the
living areas achieved the acceptance criteria below <70 structures per
mm2.
3. One of the samples taken from the roof over the garage and pool
area was above standards for asbestos by PLM. Asbestos abatement
was conducted 10/05/01 by Hazardous Elimination Corp, and repeat
testing was negative.
4. Five ambient air samples were collected for fiberglass on 11/16,
11/28/01 and analyzed by PCM. All areas samples recorded fiber levels
less than or equal to O.OIf/cc.
Tribeca Tower (105 Duane Street): Awaiting official report. Per Mr. Hoyle:
ATC Associates found that no samples were over the asbestos standard. A
mechanical hygienist was hired to HEPA vacuum and clean ducts in the
basement. An Inspector Slobek (?) was also present during cleanup activities.
Residents hired their own consultant- he used the microvac method and found
samples positive for asbestos. Non-profit lawyer also hired by residents.
Currently involved in a lawsuit.
Tribeca Park (400 Chambers Street): Awaiting official report. Per Mr.
Hoyle:
ATC Associates conducted over 200 air and bulk samples.
Air sampling; 3 samples in common areas/hallways and 2 apartment samples.
Dust sampling also conducted.
Clean-up Activities by Building Manager:
Two Asbestos Abatement companies were used for cleanup.
1. All cleanup activities were at cost to the landlords.
2. Common areas were HEPA vacuumed.
3. The outsides of buildings were HEPA vacuumed and washed down with
water (including apartment balconies).
4. The grounds were vacuumed and all bulk material was removed.
The Related Companies 2
CITY_DEP_WORBY_CANNATA_SUBP_000002739
NYC-WTC_000366791
OCR can misread numbers and units. Confirm readings against the page image before using them.