Tribeca Tower —105 Duane Street ATC Project No..09622-0014
Related Management Company, L.P. February 11, 2002
Page 2
Additionally, on December 12, 2001, ATC collected a total of ten ambient air samples, five from
within the 10 th floor common hallway and five within the 2 floor mechanical room to ascertain
,
p
the presence or absence of airborne asbestos. The samples were collected at the request of
the New York City Department of Environmental Protection (NYCDEP) in response to a tenant
complaint regarding hallway duct cleaning operations. Samples were analyzed in accordance
with the more stringent AHERA Transmission Electron Microscopy (TEM) method as set forth at
40 CFR Part 763, Subpart E, Appendix A.
Both the 10th floor hallway and 21 floor mechanical room exhibited analytical results of no
asbestos structures detected, which is below the AHERA clearance requirement. It is ATC's
opinion that duct-cleaning activities did not result in elevated asbestos levels within those
spaces, and the ambient conditions sampled at the time of testing meet an acceptable criterion
for occupancy.
On December 27, 28 & 29, 2001, during duct cleaning activities ATC collected a total of
fourteen ambient air samples, ten from within common hallways and four within the 2nd floor
mechanical room to ascertain the presence or absence of airborne asbestos. The sample
methodology, quantity, and location were agreed upon between Related Management, ATC and
H.A. Bader Consultants Inc. the tenants associations consultant. Samples were analyzed in
I accordance with the more stringent AHERA Transmission Electron Microscopy (TEM) method
as set forth at 40 CFR Part 763, Subpart E, Appendix A.
•' Based upon the analytical results from the 2"d, 50", 10th, 15th, 20th 25th, 27th, 34th, 41St floor
hallways and 2"d floor mechanical room of no asbestos structures detected, which is below
the AHERA clearance requirement. It is ATC's opinion that duct-cleaning activities did not result
in elevated asbestos levels within those spaces, and the ambient conditions sampled are
representative of the building at the time of testing and meet an acceptable criterion for
occupancy.
October 24 & 25, 2001
Floor Apartments Floor Apartments Floor Apartments
PH E 36 B, F 19 B, E
52 A, D, E, H 35 G 18 B, G, J
51 - 34 E 17 B,L
50 - 33 A, E 16 E, F, L
I 49
48
A, C, D, F, H
B, E, H
32
31
H
B, G
15
14
B, F, J, L
D, G, L
47 - 30 H 12 B, E, F, L
P1 46
45
44
E, F
B, E, G
B, E
29
28
27
A, B, D, E
-
B
11
10
9
C, L
B, D
E
I 43
42
41
A, F, G
D, F
F
26
25
24
E, F, H
B, C, D
B, C, G, H
8
7
6
D, E
B, F, H, J
D
I 40
39
38
-
D
A, B, H
23
22
21
A, B, D, G, H
A, B, F
C, E, F
5
4
1
A, B, H, K, L
C
Management,
37 B, C, D, F 20 K Lobby
NYC-WTC 000104029
OCR can misread numbers and units. Confirm readings against the page image before using them.