NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854 EMSL
Phone: 732-981-0550 Fax: 7329810551 Email:
Attn: George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Customer PO:
(EM & CA)
Received: 10/12/01 9:00 AM
P O. Box 872
Somerville, NJ 08876
Fax: (732)249-3384 Phone: 732-249-3005
EMSL Order: 050102759
Project: 53 Park Place NY NY EMSL Project ID:
Analysis Date: 10/12/01
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
Non-Asbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
53-6E Gray Teased 70.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-0021 Fibrous 10.00% Cellulose
Heterogeneous
53-6F Gray Teased 40.00% Glass 30.00% Non-fibrous (other) <1% Chrysotile
050102759-0022 Fibrous 30.00% Cellulose
Heterogeneous
53-6G Gray Teased 40.00% Glass 30.00% Non-fibrous (other) <1% Chrysotile
OS01O2759-OO23 Fibrous 30.00% Cellulose
Heterogeneous
53-6H Gray Teased 40.06% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-002^ Fibrous 40.00% Cellulose
Heterogeneous
53-6J Gray Teased 60.00% Glass 20.00% Non-fibrous (other) None Detected
050102759-0025 Fibrous 20.00% Cellulose
Heterogeneous
53-6K Gray Teased .60.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-0026 Fibrous 20.00% Cellulose
Heterogeneous
52-7A Gray Teased 15.00% Glass 5.00% Non-fibrous (other) <1% Chrysotile
050102759-0027 Fibrous 80.00% Cellulose
Heterogeneous
52-7B Gray Teased 20.00% Glass 7.02% Non-fibrous (other) 2.98% Chrysotile
J 050r0275»-002e Fibrous 70.00% Cellulose
Heterogeneous
52-7E Gray/Black Teased 10.00% Glass 30.00% Non-fibrous (other) None Detected
. 050102759-0029 Fibrous 60.00% Cellulose
Heterogeneous
52-7F Gray Teased 25.00% Glass 25.00% Non-fibrous (other) None-Detected
050102759-0030 Fibrous 50.00% Cellulose
Heterogeneous
DrewHodgden
Analyst Adrian Arav
or other approved signatory
PIM hM been known to miss asbestos in a small percentage of samples which contain asbestos. Negativs PLM results cannot be guaranteed. Samples reported as <1* or none
deteoMd should be tested with TEM. The above lest report rotates only Io the Hems tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical,
Inc, The abdre last must not bo used by the client Io claim product endorsement by NVLAP nor any agency o( the United Stales Government.
■jwXie pejnnned by EMSL Piscataway (NY Stale ELAP *11423. NVLAP »101048-Z Cormeeticut DOH PH-0266 Approved Env. Lab)_______________________________________
P iunt-1 3
CITY_21MC100_002861629
NYC-WTC_000366537
OCR can misread numbers and units. Confirm readings against the page image before using them.