NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854
EMSL
Phone: 732-981-0550 Fax: 7329810551 Email:
Attn George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Custcn-T PC:
(EM & CA)
Received; 10/12/01 9:00 AM
P C. Box 872
Somerville, NJ 08876
Fax: (732) 249-3384 Phone: 732-249-3005
EMSL Order: 050102759
Project; 53 Park Place NY NY
EMSL Project ID:
Analysis Date; 10/12/01
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
Non-Asbestos Asbestos
Sample Location Appearance Treatment 7o Fibrous % Non-Fibrous % Type
53-4F Gray Crushed 00.00% Non-fibrous (other) None Detected
050102759-0011 Non-Fibrous
Heterogeneous
53-4G Gray Crushed 40.00% Glass 30.00% Non-fibrous (other) None Detected
OSO1O2759-OO12 Fibrous 30.00% Cellulose
Heterogeneous
53-4I Gray Teased 40.00% Glass 30.00% Non-fibrous (other)
None Detected
050102759-0013 Fibrous 30.00% Cellulose
Heterogeneous
53-4K Gray Teased 40.0*% Glass 20.00% Non-fibrous (other) None Detected
050102759-0014 Fibrous 40.00% Cellulose
Heterogeneous
53-5A Gray Teased 40.00% Glass 30.00% Non-fibrous (other) <1% Chrysotile
050102759-0015 Fibrous 30.00% Cellulose
Heterogeneous
53-5C Gray Teased . 40.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-0010 Fibrous 40.00% Cellulose
Heterogeneous
53-5K Gray Teased 50.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
0501027590017 Fibrous 30.00% Cellulose
Heterogeneous
53-6A Gray teased 30.00% Glass 28.96% Non-fibrous (other) 1.04% Chrysotile
050102759-0018 Fibrous 40.00% Cellulose
Heterogeneous
53-6B Gray Teased 40.00% Synthetic 30.00% Non-fibrous (other) None Defected
050102759-0019 Fibrous 30.00% Glass
Heterogeneous
53-6D Gray Teased 40.00% Glass 27.87% Non-fibrous (other) 2.13% Chrysotile
050102759-0020 Fibrous 30.00% Cellulose
Heterogeneous
I Adrian Arav
Analyst Adrian Arav
or other approved signatory
I PLM hM been known to miss asbestos in a small percentage of samples which contain asbestos. Negative PLM resuhs canrat ba guaranteed. Samples reported as <1% or none
detected shtxjtd be tested with TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical,
Inc. The ablve test must not be used by the client Io claim product endorsement by NVLAP nor any agency tX the Unilod States GovernmenL
An^R paionned by EMSL Piscataway (NY State ELAP *11423, NVLAP #101048-2, Connecticut OOH PH-0266 Approved Etw. Lab)
Count-1 2