NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854 EMSL
• Phone: 732-981-0550 Fax: 7329810551 Email:
Attn: George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Customer PO:
(EM & CA)
Received: 10/10/01 2:40 PM
P.O. Box 872
Somerville, NJ 08876
Fax: (732) 249-3384 Phone: 732-249-3005
EMSL Order: 050102723
Project: 53 Park Place
EMSL Project ID:
Analysis Date: 10/10/01
I I
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
Non-Asbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
3-GF-1 Gray Teased 25.00% Glass 40.00% Non-fibrous (other) None Detected
0501027230001 Fibrous 35.00% Cellulose
Heterogeneous
3-2-C Gray Teased 70.00% Glass 22.00% Non-fibrous (other) None Detected
50102 723-0002 Fibrous 8.00% Cellulose
Heterogeneous
3-2-H Gray Teased 50.00% Glass 15.00% Non-fibrous (other) None Detected
r.50l027230003 Fibrous 35.00% Cellulose
Heterogeneous
53-3-C Gray Teased 55,ô/0 Glass 15.00% Non-fibrous (other) None Detected
102723-0004 Fibrous 30.00% Cellulose
Heterogeneous
53-3-G Gray Teased 45.00% Glass 10.00% Non-fibrous (other) <1% Chrysotile
50102723.0005 Fibrous 45.00% Cellulose
Heterogeneous
53-3-H Gray Teased - 55.00% Glass 10.00% Non-fibrous (other) <1% Chrysotile
050102723.0006 Fibrous 35.00% Cellulose
Heterogeneous
53-3-1 Gray Teased 60.00% Glass 10.00% Non-fibrous (other) None Detected
050102723.0007 Fibrous 30.00% Cellulose
Heterogeneous
53-3-J Gray Teased 50.00% Glass 10.00% Non-fibrous (other) None Detected
050102723-0006 Fibrous - 40.00% Cellulose
Heterogeneous
53-4-H Gray Teased 50.00% Glass 20.00% Non-fibrous (other) None Detected
050102723-0009 Fibrous 30.00% Cellulose
Heterogeneous
53-4-J Gray Teased 55.00% Glass 10.00% Non-fibrous (other) <1% Chrysotile
050102723-0010 Fibrous 35.00% Cellulose
Heterogeneous
Maurice Carchman
A4wk v
• Analyst Adrian Arav
or other approved signatory
Pi.M has been known to miss asbestos ma small percentage of samples which contain asbestos. Negative PLM results cannot be guaranteed. Samples reported as <1% or none
detected stvuld be tested with TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical,
Inc. he a test must not be used by the client to claim product endorsement by NVLAP nor any agency of the United States Government.
is ad by EMSL Piscataway (NY State ELAP #11423, NVLAP #101048-2, Connedfaa DOH PH-0266 Approved Env, Lab)
P in ount-1 1
NYC-WTC 000120132