NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854
Phone: 732-981-0550 Fax: 7329810551 Email:
Attn: George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Custc'n'.r PO:
(EM & CA)
Received: 10(12/01 9:00 AM
P.O. Box 872
Somerville, NJ 08876
Fax: (732) 249-3384 Phone: 732-249-3005
EMSL Order: 050102759
Project: 53 Park Place NY NY EMSL Project ID:
Analysis Date: 10/12/01
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
Non-Asbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
3-4F Gray Crushed 00.00% Non-fibrous (other) None Detected
;c.0+02;E, ',o„ Non-Fibrous
Heterogeneous
3-4G Gray Crushed 40.00% Glass 30.00% Non-fibrous (other) None Detected
50102759,0012 Fibrous 30.00% Cellulose
Heterogeneous
53-41 Gray Teased 40.00% Glass 30.00% Non-fibrous (other) None Detected
50102759-0013 Fibrous 30.00% Cellulose
Heterogeneous
53-4K Gray Teased 40.9M'h Glass 20.00% Non-fibrous (other) None Detected
050102759-0014 Fibrous 40.00% Cellulose
I Heterogeneous
; '53-'5A Gray Teased 40.00% Glass 30.00% Non-fibrous (other) <1% Chrysotile
5002759--0015 Fibrous 30.00% Cellulose
Heterogeneous
53-5C Gray Teased _ 40.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-0016 Fibrous 40.00% Cellulose
Heterogeneous
53-5K Gray Teased 50.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102759-0017 Fibrous 30.00% Cellulose
Heterogeneous
53-6A Gray Teased 30.00% Glass 28.96% Non-fibrous (other) 1.04% Chrysotile
050102759-0018 Fibrous - 40.00% Cellulose
53-6B Gray Teased 40.00% Synthetic 30.00% Non-fibrous (other) None Detected
050102759-0019 Fibrous 30.00% Glass
Heterogeneous
53-60 Gray Teased 40.00% Glass 27.87% Non-fibrous (other) 2.13% Chrysotile
050102759-0020 Fibrous 30.00% Cellulose
Heterogeneous
Adrian Arav
Analyst Adrian Arav
or other approved signatory
PLM has been known to miss asbestos in a small percentage of samples which contain asbestos. Negative PLM results cannot be Queranteed. Samples reported as <1% or none
detected stuld be tested with TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical,
Inc. ustnotbeused by the Client to dais product endorsement by NVLAP nor any agency of the united States Government.
ed by EMSL Piscataway (NY State FLAP #11423, NVLAP #101048-2, Connecticait DOH PH-0266 Approved Ene. Lab)
NYC-WTC 000120136