EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854
Phone: 732.981-0550 Fax' 7329810551 Fmail:
Attn: George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Customer PO:
(EM & CA)
Received: 10/12/01 9:00 AM
P.O. Box 872
Somerville, NJ 08876
Fax: (732) 249-3384 Phone: 732-249-3005
EMSL Order: 050102759
Project: 53 Park Place NY NY EMSL Project ID:
Analy s Date: 10/12/01
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
i Non-Asbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
53-2B Gray/Black Teased 10,00% Min, Wool 40.00% Non-fibrous (other) None Detected
050102759-0001 Fibrous 50.00% Cellulose
Heterogeneous
X53-2F Gray/Black Teased 10.00% Min, Wool 30.00% Non-fibrous (other) None Detected
050102759-0002 Fibrous 60.00% Cellulose
Heterogeneous
53-2G Gray Teased 5.00% Min, Wool 25.00% Non-fibrous (other) None Detected
0,50102759-0003 Fibrous 70.00% Cellulose
Heterogeneous
53-3A Gray Teased 80.DW/o Cellulose 18.88% Non-fibrous (other) 1.12% Chrysotile
050102759.0004 Fibrous
Heterogeneous
53-38 Gray Teased 75.00% Cellulose 25.00% Non-fibrous (other) None Detected
050102759-0005 Fibrous
Heterogeneous
53-3D Gray Teased _ 70.00% Cellulose 30.00% Non-fibrous (other) None Detected
050102759.0006 Fibrous
Heterogeneous
53-3E Gray Teased 5.00% Min. Wool 28,90% Non-fibrous (other) 1.10% Chrysotile
050102759-0007 Fibrous 65.00% Cellulose
Heterogeneous
53-3F Gray Teased 60.00% Cellulose 40.00% Non-fibrous (other) None Detected
050102759-0008 Fibrous
Heterogeneous
53-4A Gray Teased 40.00% Glass 30.00% Non-fibrous (other) None Detected
050102759.0009 Fibrous 30.00% Cellulose
Heterogeneous
53-4C Gray Teased 60.00% Crass 20.00% Non-fibrous (other) <1% Chrysotile
050102759.0010 Fibrous 20.00% Cellulose
Heterogeneous
Adrian Arav
Analyst Adrian Arav
or other approved signatory
PLM has been known to miss asbestos in a small percentage of samples which contain asbestos. Negative PLM results cannot be guaranteed. Samples reported as <t % or none
detected ehguld be tested with TEM. The above test report relates only to the items tested. This report may not be reproduced, except in fug, without written approval by EMSL Analytical,