NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Ambient air sampling report, Rector Street floors 4–23

Machine-extracted title · confidence 32%

Hygienetics conducted ambient air sampling in multiple Rector Street floors, Sept 19–21, 2001.

NYC-WTC_000363690–000363691
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Kygienetics® Environmental Hyg;«rieti(;s Environmental Services, Inc. 1 VJest 34th Street Phone: (212; 244-344, 7th Floor Fsx: (212) 244 g5O5 September 26, 2001 New York, NY tOOOt

Mr. Vidor Purpura Building Manager Stellar Management Two Rector Street New York, NY 10006

Re; Report of Air Sampling Results Two Rector Street -Floors 4-8,15,16,18-23 and 27

Dear Mr. Purpura:

As requested, Hygienetics Environmental Services, Inc. (Hygienetics) conducted ambient air sampling at the captioned areas. This air sampling was conducted on September 19-21, 2001.

Methodology: Air monitoring was performed by setting up a sampling train at each sampling location. Each train consisted of a high volume air sampling pump, which was calibrated to collect air in accordance with the appropriate sampling methodology (NIOSH 7400 Method for airborne fibers), attached to 0.45 micrometer pore size, 25 millimeter diameter mixed cellulose ester membrane filter cassettes with tygon tubing. Open faced cassettes were utilized for the air sampling.

Area air samples were collected at representative interior spaces on each of the referenced floors at Two Rector Street. In addition, field blank samples were also submitted to the analytical laboratory, for quality control/quality assurance (QA/QC) purposes. A total of 74 samples were submitted for analysis by Scientific Laboratories, Inc. a New York State Department of Health (ELAP) Approved laboratory.

On-site pump calibration was performed with a high-flow rotameter, at the start and completion of each sample collection period, to ensure an accurate volumetric reading. The rotameter’s calibration was confirmed prior to its use on-site, utilizing a Mini Buck Model M-30 bubble calibrator, a primaiy calibration standard.

Sample Data and Discussion

Optical Phase Contrast Microscope Analysis: Please refer to copies of the attached analytical laboratory’s report for the results of the sampling conducted. In summary, the levels of measured airborne fibers present during the sampling period were relatively low, and did not approach or exceed any applicable, enforceable industrial exposure limits as set by governmental agencies.

At the present time, there are no non-industiial indoor air quality standards, or permissible exposure limits for airborne asbestos. However, a generally accepted airborne fiber concentration for “Clean Air” subsequent to asbestos abatement activities in commercial buildings in New York City is 0.01

CITY_21MC100_002841720

NYC-WTC_000363690

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363690Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →