NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

TEM/ASTM dust method label, 5755, 2001

Machine-extracted title · confidence 32%

ATC TEM dust method practice document referencing AHERA/ASTM 5755.

NYC-WTC_000363392–000363403
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 12/11/2001 17:07 FAI 212 353 8306 ATC ®012

flSlh D5755 regular basis, and retain these records in ihc laboratory, in number for the Cu peak and be cenain that readings arc accordance with the laboratory's quality assurance program. within ±10 eV. 20.2 Record calibrations in a log book along with dates of 20.4.2 Collect a standard EDXA of crocidolite asbestos calibration and the attached backup documentation. (NISTSRM 1866). 20.3 A calibration list for the instrument is as follows: 20.4.2.1 The elemental analysis of the crocidolite must 20.3.1 TEM: resolve the Na peak. 20.3.1.1 Check the alignment and the systems operation. 20.4.3 Collect a standard EDXA of chrysotile asbestos. Refer to the TEM manufacturer’s operational manual for 20.4.3.1 The elemental analysis of chrysotile must resolve detailed instructions. both Si and Mg on a single chrysotile fiber, 20.3-1-2 Calibrate the camera length of the TEM in elec­ 20.5 Ultrasonic bath calibration shall be performed as tron diffraciion (ED) operating mode before ED patterns of follows: unknown samples are observed. Camera length can be mea­ 20.5.1 Fill the bath water to a level equal to the height of sured by using a carbon coated grid on which a thin film of -suspension in the glass sample container that will be used for gold has been sputtered or evaporated. A thin film of gold is the dust analysis. Operate the bath until the water reaches the evaporated, on the specimen TEM grid to obtain zone-axis equilibrium temperature. £D patterns superimposed with a ring pattern from the poly- 20.5.2 Place 100 mL of water (at approximately 20*Q in crystalline gold film. In practice, it is desirable to optimize another 200-mL glass sample container, and record its the thickness of the gold film »that only one or two sharp temperature. rings are obtained on the superimposed ED pattern. Thick 20.5.3 Place the sample container in the water in the gold films win tend to mask weak difiraction spots from the ultrasonic bath (with the power turned oil). After 60 s, fibrous particles. Since the unknown d-spaeings of most remove the glass container and record its temperature. interest in asbestos analysis are those which lie closest to the 20.5.4 Place 100 mL of water (at approximately 20*0 in transmitted beam, multiple gold rings from thick films arc another 200-mL glass sample container, and record iis unnecessary. Alternatively, a gold standard specimen can be temperature. used to obtain an average camera constant calculated for that 20.5.5 Place the second sample container into the water in particular, insmiment and can then be used for ED patterns the ultrasonic bath (with the power turned on). After 60 s, of unknowns taken during the corresponding period. remove the glass container and record its temperature. - 20.3-1-3 Perform magnification calibration at the fluores­ 20.5.6 Calculate the rate of energy deposition into the cent screen. This calibration must be performed at the sample container using the following formula: magnification used for structure counting. Calibration is /J - 4.185 X IX p X ~ *1? performed with a grating replica (7.47) (for example, one (2) t containing at least 2160 lines/mm). where: (a) Define a field of view on the fluorescent screen. The 4.185 -Joules/cal, field of view must be measurable or previously inscribed with * energy deposition, watts/mL, a scale or concentric circles (all scales should be metric). 6i = temperature rise with the ultrasonic bath not oper­ (h) Frequency of calibration will depend on the service ating, ’C, history of the particular microscope. = temperature rise with the ultrasonic bath operating, (c) Check the calibration after any maintenance of the ’C. microscope that involves adjustment of the power supply to r 3 time in seconds, dO s (W.S.3 and 20.5.5), the lens or the high voltage system or the mechanical a -specific beat of the liquid in the glass ample disassembly of the electron optical column (apart from container, 1.0 cal/g, and filament exchange). p - density of the liquid in the glass sample container, (d) The analyst must ensure that the grating replica is l.Og/cm’ placed at the same distance from the objective lens as the 20.5.7 Adjust the opraating conditions of the bath so that spccuncn, the rate of energy deposinon is in the range of 0.08 to 0.12 (c) For insbuments that incorporate a eucentric tilting MW/m^ as defined by this procedure. specimen stage, all speciniens and the grating replica must be placed at the eucentric position. 21. Precision sad Blas 20.3.1.4 The smallest spot size of the TEM must be 21.1 frecuion—The predsiooofthc procedure in this test checked. method is being determined using round robin data from (o) At the crossover point, photograph the spot size at a participating laboratories. screen magnification of 15 000 to 20000X. An exposure 21.2 Since there is no accepted reference material time of 1 s is usually actuate. suitable for determining the bias of the procedure tn this test (b) The measured spot size must be less than or equal to method, bias has not been determined (see Specification 250 nm. D 3670). 20.4 EDXA: 20.4.1 The resolution and calibration of the EDXA must Not* 3—Round robin dau is under development and will be I be verified. presented as a irscerob report 20.4.1.1 Coilea a standard EDXA Cu peak from the Cu grid. 22. Keywords 20.4.1.2 Compare the X-ray energy versus channel 22.1 asbestos; nucrovacuuming; settled dust; TEM

9

CITY_21MC100_002847946

NYC-WTC_000363400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →