NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗ATC TEM dust method practice document referencing AHERA/ASTM 5755.
NYC-WTC_000363392–000363403OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document 12/11/2001 17:07 FAJ 212 353 8306 ATC @011
® D5755
Materials in Schools document (4). Record, for each AHERA 17. Sample Storage miciure identified, the length and width measurements. 17.1 The washed-out sample cassettes can be discarded 16.3 Record NSD ^o Structures Detected) when no after use. iiiructures are detected in the grid opening. 17.2 Sample grids and unused filter sections (7.18) must 16.4 Identify structures classified as chrysotile identified be stored for a minimum of one year. by either electron diffraction or X-ray analysis (7.3) and recorded on a count sheet Verify at least one out of every ten 18. Reporting chrysotile structures by X-ray analysis. 18.1 Report the following information for each dust 16.S Structures classified as amphiboles by X-ray analysis sample analyzed: and electron diffraction are recorded on the count sheet. For 18.1.1 Concentration in strucmres/cm-. more information on identification, see Yamate, et al, (7) or 18.1.2 The analytical sensitivity. Chatfield and Dillon (8). 18,1.3 Types of asbestos present. 16.6 Record a typical electron diffraction pattern for each IB. 1.4 Number of asbestos structures county. type of asbestos observed for each group of samples (or a 18.1.5 Effective filtration area. minimum of every five samples) analyzed. Record the 18.1.6 Average size of the TEM grid openings that were micrograph number on the count shed. Record at least one counted. X-ray spectrum (ar each type of asbestos observed per 18.1.7 Number of grid openings examined. sample. Attach the print-outs to the baric of the count sheet 18.1.8 Sample dilution used. If the X-ray spectrum is stored, record the file and disk 18.1.9 Area of the surface sampled. number on the count sheet 18.1.10 Listing of size data for each structure counted. 16.7 Counting Rules: 18.1.11 A copy of the TEM count sheet or a complete I6.7.I At a screen magnification of between IS 000 and listing of the raw data. An example of a typical count sheet is 20 OOOX evaluate the grids for the most concentrated ample shown in Appendix XI. loading; reject the sample if it is estimated to contain more 18.2 Determine the amount of asbestos in any accepted than 50 asbestos structures per grid opening. Proceed to the sample using the following formula: next lower concentrated sample until a set of grids are £FriX lOOraLx^mt , obtained that' have less than 30 asbestos structures per grid — = asbestos structures/cm^ (1) opening. GOV.GOA'kVkSPL 16.8 Analytical Sensitmly—Asi analytical sensitivity of where: < approximately lOOO asbestos structures per square centi #STR = number of asbestos structures counted. metre (calculated for the detection of a single asbestos EFA = effective filter am of the final sampling filter, structure) has been designed for this analysis. This sensitivity GO - number Of grid openings counted, can be achieved by increasing the amount of liquid filtered, GOA " average grid opening area, increasing the number of grid openings analyzed, or de SPL ■ surfece area sampled, cm^, and creasing the size of the final filter. Occasionally, due to high r » volume of sample filtered in step 10.4.9. repre particle loadings or high asbestos concentration, this analyt- senting the actual volume taken from the original ical sensitivity cannot be practically achieved and stopping 100 mL suspension, mL, rules apply. 19. Quality Control/Quality Assurance 16.9 Limit ef Deteciiori—The limit of detection for this 19.1 In general, the laboratory’s quality control checks axe method is defined as, at a minimum, the counting of four used to verify that a system is performing according to asbestos structures during the TEM analysis. If less than four spedfications regarding accuracy and connsteney. In an asbestos structures are counted during the analysis then the analytical laboratory, spiked or known quantitative samples analytical result which will be reported will be less than the are normally used. However, due to the difficulties in limit of detection and a “less than'' sign (<) will appear preparing known quantitative asbestos samples, routine before the number. All data shall be provided in the labo quality control testing focuses on re-analysis of samples ratory report (duplicate recounts), 16.10 Stopping Rules: 19.1.1 Re-aualyze samples at a rate of Vio of the sample 16.10.1 The analysis is stopped upon the completion of sets (one out of evoy ten amples analyzed not including the grid square that achieves an analytical sensitivity of less laboratory blanks). The re-analysis shall consist of a second than 1000 asbestos structures per square centimetre. sample preparation obtained fiom the final filter. 16.10.2 If an analytical sensitivity of 1000 asbestos Struc 19.2 In addition, quality assurance programs must follow tures per square centimetre cannot be achieved after ana the criteria shown in the USEPA Aibtaot^CMatnblg Mate lyzing ten g^ openings then stop on grid opening No. 10 or rials in Schools document (4) and in the NIST/NPLAP the grid opening which contains the 100th asbestos structure, Program Handbook for Airborne Asbestos Analysis docu whichever comes first. A minimum of four grid squares shall ment (6). These documents describe sample custody, sample be analyzed for each sample. preparation, blank checks for contamination, calibration, 16.I0JL1 If the analysis is stopped because of the 100th sample analysis, analyst qualifications, and technical facili ’I structure rule, the entire grid square containing the lOOtb ties. structure must be counted. 16.11 After analysis, remove the grids from the TEM, and 20. Calibrations replace them in the appropriate grid storage holder. 20.1 Perferm cabbrations of the insmimentation on a
8
CITY_21MC100_002847945
NYC-WTC_000363399
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
13 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
8 shared non-person entities · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
13 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362205
SOP validation study references and definitions for asbestos Part 763 sections.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similar indexed content
NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
Similar indexed content
NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similar indexed content
NYC-WTC_000208957
Document excerpt outlining standard test methods for analyzing asbestos concentrations in dust samples using microscopy techniques.
Similar indexed content
NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
Similar indexed content