Information sheet on asbestos design and analysis standard D5755, undated revision notes.

NYC-WTC_000318556–000318564
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DK. 14,2001 2:0?PM lATL NO, 095 P. 4 ® SS7SS

regular basis, and retain the^ records in the laboratory, in number for the Cu peak and be certain that readings are accordance with the laboratory's quality assurance program. within ±10 eV. 20.2 Record calibrations in s log book along with dates of 20.4.2 Collect a standard EDXA of crocidolite asbestos calibration and the attached backup documentation. (NIST SRM 1866). 20.3 A calibration list for the jnstrumcni is as follows: 20.4.2.1 The elemental analysis of the crocidolite must 20.3.1 TEM: resolve the Na peak. 20.3.1.1 Check the alignment and the systems operation. 20.4.3 Collect a standard EDXA of chrysotile asbestos. Refer to the TEM manufacturer's operational maaual for 20.4.3.1 The elemental analysis of chrysotile roust resolve detailed instructions. both Si and Mg on a single chrysotile fiber, 20.3.1.2 Calibrate the camera length of the T&M in elec­ 20,5 Ulirasooic bath calibration shall be performed as tron difTraaion (ED) operating mode before ED patterns of follows: unknown samples are observed. Camera length can be mea­ 20.5.1 Fill the bath water to a level equal to the height of sured by using a carbon coated grid on which a thin (Um of suspension in the glass ample container that will be used for gold has bees spunered or evaporated. A this film of gold is the dust analysis. Operate the bath until the water reaches the evaporated on the specimen TEM grid to obtain zone-axis equilibrium temperature. ED patterns supcriniposed with a ting panera from the poly- 20.5,2 Platt JOO bjL of water (at approximately 2O’C) ia crystaUine gdd film. In practice, it is desirable to optimize another 200-mL glass sample container, and record its the thickness of the gold film so that only one or two sharp temperature, rings are obtained on the superimposed ED pattera. Thick 20-5-3 Place the sample container in the water ia the I gold films will tend to mask weak diffraction spots from the ultrasonic hath (with the. power turned ofl). After 60 s, 1 fibrous panids. Since the unknown d-spacings of most remove the glass container and record its lemperature, interest in asbestos analysis are those which lie closest to the 20.5.4 Place 100 mL of water (at approximately 20*C) ia sransmiued beam, multiple gold rings from thick films are another 200-mL glass sample container, and record iu unnecessary. Alternatively, a gold standard specimen can be temperature. used to obtain an average camera constant calculated for that 20-53 Place the second sample container into the water in panicular instrument and can then be used for ED patterns the ultrasonic bath (with the power turned on). After 60 s, M of unknowns taken during the corresponding period. remove the glass container and record is temperature. I • 20.3.1.3 Perform magnification calibration at the fluores­ 20.5.6 Calculate the rate of energy deposition into the cent screen. This calibration must be performed at the sample container using the following formula: magnification used for structure counting. Calibration is (S, - a,) JJ = 4.185 » o X p X —— (2) perfonaed with a grating replica (7.47) (for enample. one r containing at least 2160 lines/mm). where: (c) Define a field of view on the fluorescent screen. The 4.185 ■= Joules/cal, field of view must be measurable or previously inscribed with J? energy deposition. wans/mL, a scale or concentric circles (all scales should be metric). f. C3 temperature rise with the ultrasonic bath not ops?. (h) Frequency of calibration will depend on the service axing. X, history of the panicular microscope. fa IE temperature rias with the ultrasonic bath operating, (c) Check the calibration after any maintenance of the °C. microscope that involves adjusimem of the power supply to r a tune in seconds. 60 s (20.5.3 and 203.5), the lens or the high voltage system er the mechanical e specific heat of the liquid in the glass sample dirasssmbly of the electron optica) column (apart from coatainsr, 1.0 cal/g, and filament exchange). P density of the liquid in the glass ample container, (d) The analyst mmt ensure that the grating replica is 1.0 g/cm^. placed at the same distance frera the otyeexive Leas as the 20.5.7 Adjust the operatins conditions of the bath so that specimen. the rate of saet^ deposition is in the range of 0,08 to 0.12 L (f) For instruments that incorporate a eusentric tilting specimen stage, all ^redmens and the grating replica must be placed at the eucentric position. defined by this procedure. 23. Py^cssioa and Stas 20.3.1,4 The smallest 901 size of the TEM must be 8 checked. (a) At the erossover point, photograph the spot size at a screen magnification of 15 000 to 20 000X. An exposure 21.1 Preoj/on—The precision of the procedure in this test method is being determined using round robin data from partidpating laboratories. 21.2 ^uzr—Since there is no accepted reference material time of 1 $ is usually adequate. suitable for detennining the bias of the procedure in this test . (6) The measured spot aze must be less than or equal to method, bias has not been determine (sse Specification 250 nm. D3670). 20,4 EDX4. I 20.4.1 The resolution and calibration of the EDXA waist be verified. 20.4.1.1 CoJlan 3 standard EDXA Cd peak from the Cu Note 3=-Round robin data is under developmcBt and ml) piese&ted as a lEsxareh cepait.

arid. 22. KeywunSs 20.4.1.2 Compare the X-ray energy versus channel 22.2 asbestos; microrwacuuraing; settled dust; TEM

9

CITY_21MC100_011092783

NYC-WTC_000318564

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318564Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →