TABLE 4-1
WTC Background Study
Sampling and Analytical Procedures Summary
Analytical Required Detection
Media Sampling Points Sampling Method Description Analytical Method
Parameters Limits'
This is a micro vacuuming method. By taping three wipe-sampling
Asbestos ASTM D 5755-95 templates together, three co-located samples were collected from ASTM D 5755-95 1000 structures/cc
Settled Dust Carpets, fabric furniture or
each location.
Porous Soft drapery in areas of activity
surfaces (living rooms, family rooms) This is a micro vacuuming method. By taping three wipe-sampling
Lead ASTM E 1973-99 templates together, three co-located samples were collected from SW-846 601 OB <25 ug/ft^
each location.
Asbestos ASTM D 6480-99 Wipe Samples (samples win be collected on the same wipe as MMVF) ASTM D 6480-99 (wipe) 1000 structures/cc
Lead HUD Appendix 13.1 Wipe Samples SW-846 601 OB <25 ug/ft"
Horizontal surfaces of Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 <2 ng/m"
Settled Dust
tables or counters and bare
Non-porous PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C <0.3 mg/m"
floors, ceilings and walls in
Hard
areas of activity (living
surfaces Total Dust HUD Appendix 13.l" Wipe Samples No Formal Method (NIOSH 7500 Modified) No detection limit required
rooms, family rooms)
Silica, calcite,
HUD Appendix 13.1" Wipe Samples. All parameters were collected on one wipe. NIOSH 7500 (XRD) Background
gypsum
MMVF ASTM D 6480-99 Wipe Samples (samples will be collected on the same wipe as asbestos) EMSL MSD0310 Background
Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA PCM 0.0009 f/cc
Asbestos NIOSH 7400
wkgroup Practical Quantitation Limit (PQL) method. TEM 0.0005 f/cc
Air pump operated at 10L/min for 8 hours to achieve the COPC
Lead NIOSH 7300 SW-846 601 OB 0.1 ug/m"
Areas of known activity wkgroup PQL
Indoor Air
(living rooms, family rooms) Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC
NIOSH 7500 NIOSH 7500 (XRD) 0.5 ug/m"
gypsum wkgroup PQL
Air pump operated at lOUmin for 8 hours to achieve the COPC
mmvf’ NIOSH 7400 EMSL MSD0310 <0.01 f/cc
wkgroup Practical Quantitation Limit (PQL)
Asbestos: PLM NYS 198.1 followed by
Bulk dust samples* were collected from AC window type unit filters, Background
Asbestos; lead; Attachment 5 of the QAPP TEM NYS 198.4
brushed with a disposable brush into a stainless steel bowl and
AC window units (collection silica, calcite, "HVAC Or Air Conditioner
transferred into sample containers. If the volume required was not ____________ Lead: SW-846 601 OB____________ <25 uq/ft"
Bulk Dust of bulk dust sample from gypsum; MMVF Filter Bulk Collection
sufficient for all analyses, the sample analysis was prioritized as Silica, calcite, gypsum: NIOSH 7500 (XRD) Background
the unit air filters). Protocol” prepared by TRC
follows: asbestos, lead, silica, calcite, gypsum, MMVF, PAHs, and MMVF: PLM NYS 198.1/EMSL MSD 0310 Background
Solutions Inc.
dioxins. ___________ Dioxins: SW-846 8290___________ <2 ng/m"
Dioxins, PAHs
PAHs: SW-846 8270 <0.3 mg/m"
NOTES: 'Required Detection limits are Tier III Levels from "Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health Based Benchmarks" prepared by
the Contaminants of Potential Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group
" Wipe samples for total dust and silica, calcite and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available.
n ’ No standardized sampling method exists for this parameter. On the assumpition that this fibrous material behaves in the air in the same way as asbestos, NIOSH 7400 will be utlized.
Analysis via EMSL MSD 0310 (see the EMSL SOP in Appendix C).
‘ No less than 5 grams and up to 20 grams of dust are required to analyze for asbestos, lead, silica, calcite, gypsum, and MMVF.
At least 10 grams of dust for PAHs and 30 grams for dioxins.
S LEGEND: < = less than
n f/cc = fibers per square centimeter
o mg/m" = milligrams per square meter
o
ng/m" = nanograms per square meter
I
ug/ft" = micrograms per square foot
o ug/m’ = micrograms per square meter
CJ