NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Draft EPA/NYC response background report for WTC air sampling, March 2003.
NYC-WTC_000318918–000318994OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TAr- “4-1
WTC Background Study Sampling and Analytical Procedures Summary
Analytical Required Detection Media Sampling Points Sampling Method Description Analytical Method Parameters Limits’ This is a micro vacuuming method. By taping three wipe-sampling Settled Dust Carpets, fabric furniture or Asbestos ASTM 0 5755-95 templates together, three co-located samples were collected from ASTM D 5755-95 1000 stnjctures/cc Porous Soft drapery in areas of activity each location. surfaces (living rooms, family rooms) This is a micro vacuuming method. By taping three wipe-sampling Lead ASTM E 1973-99 templates together, three co-located samples were collected from SW-846 6010B ' <25 ug/ft’ each location. Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) 1000 stroctures/cc Lead HUD Appendix 13.1 Wipe Samples SW-846 6010B <25 ug/ft’ Horizontal surfaces of Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 <2 ng/m’ Settled Dust tables or counters and bare Non-porous PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C <0.3 mg/m’ floors, ceilings and walls in Hard areas of activity (living surfaces Total Dust HUD Appendix 13.l’ Wipe Samples No Formal Method (NIOSH 7500 Modified) No detection limit required rooms, family rooms) Silica, calcite, HUD Appendix 13.1^ Wipe Samples. All parameters were collected on one wipe. NIOSH 7500 (XRD) Background gypsum MMVF ASTM D 6480-99 Wipe Samples EMSL MSD 0310 Background Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA PCM 0.0009 f/cc Asbestos NIOSH 7400 wkgroup Practical Quantitation Limit (PQL) method. TEM 0.0005 f/cc Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 . SW-846 6010B 0.1 ug/m’ Areas of known activity wkgroup PQL Indoor Air (living rooms, family rooms) Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) 0.5 ug/m’ gypsum wkgroup PQL Air pump operated at lOL/min for 8 hours to achieve the COPC MMVF’ NIOSH 7400 EMSL MSD 0310 <0.01 f/cc wkgroup Practical Quantitation Limit (PQL)
Asbestos: PLM NYS 198.1 followed by Bulk dust samples* were collected from AC window type unit filters, Background Asbestos: lead; Attachment 5 of the QAPP TEM NYS 198.4 brushed with a disposable brush into a stainless steel bowl and AC window units (collection silica, calcite, “HVAC Or Air Conditioner <25 ug/ft’ transferred into sample containers. If the volume required was not Lead: SW-846 601 OB Bulk Dust of bulk dust sample from gypsum; MMVF Filler Bulk Collection sufficient for all analyses, the sarripla analysis was prioritized as Silica, caicite, gypsum: NIOSH 7500 (XRD) Background the unit air fillers). Protocol” prepared by TRC follows: asbestos, lead, silica, calcite, gypsum, MMVF, PAHs, and MMVF: PLM NYS 198.1/EMSL MSD 0310 Background Solutions Inc. dioxins. Dioxins: SW-846 8290 <2 ng/m’ Dioxins. PAHs PAHs: SW-846 8270 <0.3 mq/m’'
2 NOTES: 'Required Detection limits are Tier III Levels from "Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health Based Benchmarks" prepared by H the Contaminants of Potential Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group ’ Wipe samples for total dust and silica, calcite and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available. ’ No standardized sampling method exists for this parameter. On the assumpition that this fibrous material behaves in the air in the same way as asbestos. NIOSH 7400 will be utlized. Analysis via EMSL MSD 0310 (see the EMSL SOP in Appendix C). Ri ‘ No less than 5 grams and up to 20 grams of dust are required to analyze for asbestos, lead, silica, calcite, gypsum, and MMVF. At least 10 grams of dust for PAHs and 30 grams for dioxins. o LEGEND: < = less than o! f/cc = fibers per square centimeter o mg/m’ = milligrams per square meter
(JI
Ui ng/m’ = nanograms per square meter ug/ft’ = micrograms per square foot ug/m’ = micrograms per square meter DRAFT
NYC-WTC_000318991
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
30 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436532
Financial health dept report analyzing a publication on WTC dust constituents and related asbestos topics, Dec 2004.
15 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301668
Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.
16 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338048
Final health investigation report on airborne and dust exposures in Lower Manhattan after WTC collapse.
16 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276826
Final investigation report on airborne exposures to dust at World Trade Center recovery site.
16 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
32 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
32 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
19 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
21 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362040
City data extract; WTC health and environmental services data.
17 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
21 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000177588
Summary of the ASTM D 5755-95 tape sampling method used for asbestos analysis on carpets and drapery at WTC sites.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363197
Table 4-1 summary for WTC micro vacuuming sampling and asbestos results.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281769
Description of micro vacuuming and sampling locations for asbestos/lead testing.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
Similar indexed content
WTC background study interim final report prepared for FEMA and EPA contractors.
Similar indexed content
NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similar indexed content
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content
NYC-WTC_000436532
Financial health dept report analyzing a publication on WTC dust constituents and related asbestos topics, Dec 2004.
Similar indexed content