NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 145 pages

WTC Background Study, EPA report draft

Machine-extracted title · confidence 28%

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

NYC-WTC_000320385–000320529
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z TAr- "4-1 o o co

WTC Background Study ■D Sampling and Analytical Procedures Summary c o CT o o o' Ca5 ro ■D o Media Sampling Points Analytical Sampling Method Required Detection O 4^ Parameters Description Analytical Method 3. tn Limits’ 03 oo This is a micro vacuuming method. By taping three wipe-sampling Asbestos ASTM D 5755-95 O Settled Dust Carpets, fabric furniture or templates together, three co-localed samples were collected from ASTM D 5755-95 1000 structures/cc o _____________________ each location._____________________ o Porous Soft drapery in areas of activity c surfaces (living rooms, family rooms) This is a micro vacuuming method. By taping three wipe-sampling 3 Lead ASTM E 1973-99 templates together, three co-localed samples were collected from SW-846 601 OB <25 ug/ft’ CD each location. Asbestos ASTM D 6480-99 Wipe Samples ASTM □ 6480-99 (wipe) 1000 struclures/cc Lead HUD Appendix 13.1 Wipe Samples SW-846 6010B <25 ug/ft’ Horizontal surfaces of Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 <2 ng/m’ Settled Dust tables or counters and bare Non-porous PAHs ASTM D 6661-01 Wipe Samples floors, ceilings and walls in ASTM 6661-01/SW-846 8270C <0.3 mg/m* Hard areas of activity (living surfaces Total Dust HUD Appendix 13.f Wipe Samples No Formal Method (NIOSH 7500 Modified) No detection limit required rooms, family rooms) Silica, calcite, HUD Appendix 13.f Wipe Samples. All parameters were collected on one wipe. NIOSH 7500 (XRD) Background gypsum MMVF ASTM D 6480-99 Wipe Samples EMSL MSD 0310 Background Air pump operated at tOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA PCM 0.0009 f/cc Asbestos NIOSH 7400 wkgroup Practical Quantitation Limit (PQL) method. TEM 0.0005 f/cc Air pump operated at lOUmin for 8 hours to achieve the COPC Lead NIOSH 7300 SW-846 6010B 0.1 ug/m’ Areas of known activity wkgroup PQL Indoor Air (living rooms, family rooms) Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) 0.5 ug/m’ gypsum wkgroup PQL Air pump operated at lOUmin for 8 hours Io achieve the COPC MMVF’ . NIOSH 7400 EMSL MSD 0310 <0.01 f/CC wkgroup Practical Quantitation Limit (PQL)

Asbestos: PLM NYS 193.1 followed by Bulk dust samples* were collected from AC window type unit filters. Background Asbestos; lead; Attachment 5 of the QAPP TEM NYS 198.4 brushed with a disposable brush into a stainless steel bowl and AC window units (collection silica, calcite, ■HVAC Or Air Conditioner <25 uq/ft’ transferred into sample containers. If the volume required was not _________ Lead: SW-846 6010B__________ Bulk Dust of bulk dust sample from gypsum; MMVF Filler Bulk Cotlection sufficient for all analyses, the sample analysis was prioritized as Silica, calcite, gypsum: NIOSH 7500 (XRD) Background the unit air filters). Protocol" prepared by TRC follows: asbestos, lead, silica, calcite, gypsum, MMVF, PAHs, and MMVF: PLM NYS 198.1/EMSL MSD 0310 Background Solutions Inc. dioxins. _________ Dioxins: SW-846 8290_________ <2 ng/m^ Dioxins, PAHs PAHs: SW-846 8270 <0.3 mg/m^ ■ Q H NOTES: ’Required Detection limits are Tier III Levels from "Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health Based Benchmarks' prepared by K the Contaminants of Potential Concern (COPC) Committee of the World Trade Center Indoor Air Taskforce Working Group I ’ Wipe samples for total dust and silica, calcite and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available. ro ’ No standardized sampling method exists for this parameter. On the assumpition that this fibrous material behaves in the air in the same way as asbestos, NIOSH 7400 will be utlized. S Analysis via EMSL MSD 0310 (see the EMSL SOP in Appendix C). o ‘ No less than 5 grams and up to 20 grams of dust are required to analyze for asbestos, lead, silica, calcite, gypsum, and MMVF. o- - - At least 10 grams of dust for PAHs and 30 grams for dioxins. 1^ LEGEND: < = less than o f/cc = fibers per square centimeter o mg/m’ = milligrams per square meter o• on co to iC. ng/m^ - nanograms per square meter ug/ft’ = micrograms per square foot ug/m’ = micrograms per square meter draft

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320458Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →