z Z WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies o co

Analytical '2 o o Media Sampling Points Parameters Sampling Method Proposed Description Analytical Method Proposed U c CT This is,a micro vacuuming method. Three co-located samples will o' Settled Dust Carpets, fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95 o> be collected from each location. U cn Porous Soft drapery in areas of activity O o 3. surfaces (living rooms, family rooms) This is a micro vacuuming method. Three co-located samples will 03 tn Lead ASTM E 1973-99 SW-846 6010B be collected from each location. o o Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) o c Lead HUD Appendix 13.1 Wipe Samples SW-846 601OB 3CD Horizontal surfaces of Dioxins ASTM D 6661-01 Settled Dust Wipe Samples ASTM 6661-01/SW-846 8290 tables or counters and bare Non-porous floors, ceilings and vails in PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C Hard areas of activity (iving surfaces Total Dust HUD Appendix 13.1~ Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified) rooms, family ro< ms) Silica, calcite, HUD Appendix 13.1** Wipe Samples. Ail parameters will be collected on one wipe. NIOSH 7500 (XRD) gypsum MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300 Aar pump operated at lOUmin for 8 hours to achieve the COPC PCM NIOSH 7400 follovred by TEM AHERA Asbestos NIOSH 7400 wkgroup Practical Quantitation Limit (PQL) method. Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 SW-846 6010B wkgroup PQL Air pump operated at 2L/min for 8 hours. Pilot Clean-up study only SW-846 8270 (Analytical method with be PAHs NIOSH 5515 for worst case scenarios. modified to achieve the COPC wkgroup PQL Areas of known activity Indoor Air (living rooms, family rooms) Air pump operated at 25L/min for 35 hours. This modification is not Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290 only for worst case scenarios. Silica, calcite, Air pump operated at 2.5Umin for 8 hours to achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) gypsum wkgroup PQL

MMVF Assumed that if behaves the same as asbestos, samples will be NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling. Bulk samples will be collected from HVAC or AC window type unit Asbestos PLM NYS 198.1 followed by Bulk Sample filters, shaken into a plastic bag and transferred into the sample TEM NYS 198.4 container. (If the volume required is not sufficient for all analyses, the sample Lead Bulk Sample SW-846 601OB HVAC systems and AC will be analyzed for asbestos only. units (collection of bulk dust (If the volume required is not sufficient for all analyses, the sample PAHs Bulk Sample SW-846 8270 Bulk Dust sample from the unit air will be analyzed for asbestos only. filters). Background study (If the volume required is not sufficient for all analyses, the sample only. Dioxins Bulk Sample SW-846 8290 will be analyzed for asbestos only. Silica, calcite, (If the volume required is not sufficient for all analyses, the sample Bulk Sample NIOSH 7500 (XRD) gypsum will be analyzed for asbestos only. (If the volume required is not sufficient for all analyses, the sample MMVF Bulk Sample PLM NYS 198.1/EMSL MSD.0300 will be analyzed for asbestos only.

NOTE: ** Wipe samples for silica, jcatdte and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available. r I r I I

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165015Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000107379 · Box DEP Box 38

Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.

Similar indexed content

Compare copies and versions →