NYC 9/11 Public Portal Document
ASBESTOS PROJECT MONITOR AND AIR SAMPLING CONTRACT
A. Introduction
All work performed under this contract must be in compliance with all applicable, relevant, and
appropriate regulations and Scope of Work, including but not limited to those of the United
States Environmental Protection Agency (USEPA), the United States Department of Labor,
Occupational Safety and Health Administration (OSHA), the New York State Department of
Labor (NYSDOL), the New York State Department of Health Environmental Laboratory
Approval Program (ELAP) and the New York City Department of Environmental Protection
(NYCDEP). This project shall involve coordinating and monitoring the clean up of debris and air
sampling from building apartments in the vicinity of the World Trade Center explosion site.
B. Qualifications
The Third Party Air Monitor and Air Sampling Firm shall be independent of the asbestos
abatement contractor. The firm shall have extensive experience in the performance of
comparable work at large asbestos projects in the City of New York. The firm’s violation
history shall be a significant factor in meeting the qualification requirements.
Project Monitors
The Project Monitors must possess valid NYS Asbestos Project Monitor certificates. Monitors
must have served as a third party project monitor on at least 20 asbestos abatement projects.
Project Monitor must have performed final clearance inspections on at least 50 asbestos
abatement projects.
Technicians
Air monitoring Icchnicians must possess valid NYS Asbestos Project Sampling Technician
(APST) certificates. Technicians must have performed air sampling for at least 6 months.
Proof of qualifications must be presented upon request.
Equipment
Sampling equipment must be in sufficient quantity to provide the amount and type of samples
required for this project without delay of project completion time. At a minimum the following
equipment are required: air-sampling pumps vdth flow rate capacities of 2 to 10 liters per minute,
tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of
0.45pm(TEM).
C. Specifications
Clean up activities shall be scheduled for 20 to 30 units per day. Air sampling shall also be
provided at 10 to 20 units where clean up activities are not scheduled. Sufficient personnel and
equipmentshall be available for project monitoring and sampling.
CITY_21MC100_002847553
NYC-WTC_000362912
OCR can misread numbers and units. Confirm readings against the page image before using them.