JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York ^0003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalfs Eddy Inc. ELAP Lab Code: 11029
Analyte; ASBESTOS
3 Werner Way. Suite 310 NIOSH and A'PA ' Ctrfe: 100273
Dale Received: 9/29/01
Lebanon, NJ 08833 NVLAP Lab Cove '01953
Date Analyzed; 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B386
Site: i 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCATION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE#
20009 20th Floor/ Area of Damage/ South East BROWN NO 0% CELL 25%
9/27/01 Corner of Building/ Sample of Debris FBGL 15%
11115 NFIB 60%
20-009
INSUFFICIENT MATERIAL SUBMITTED “TEM RECOMMENDED *"NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chiysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Woo!
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SyNF = Synthetic Fibers
Ail samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = AnthophylKe Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL “Wollastonite
■ Instrumentation: HSHR = Horse Hair
OTHR “ Other
Olympus PLM, Model BH-2.'VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Anatytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analyticai Results" shall not be reproduced except in full, without the writte .
: approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbeslos-
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected, area. Quantitation of asbestos content was .
■ determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbebto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 3 of 3