NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: {212) 420-6092
Project No.: 01-2102
Metcalf & Eddy InC; ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AlPA i.sbCode; 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
Batch #; 01098385
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB*
CLIENT'S SAMPLE #
4009 4tti Floor/ South East/ Floor/ Sample of GRAY NO 0% CELL 5%
FBGL 20%
9/28/01 Debris
11055 NFIB 75%
4-009
‘INSUFFICIENT MATERIAL SUBMITTED “TEM RECOMMENDED —NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos • CELL = Cellulose
■Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
Olympus PLM, Model BH-2/VM Stereomicroscope, Model i OTHR = Other
VMZ 1x-4x. TSulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials, only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine Fibers below the resolution of the light microscope. The value of this method is limited to the quantitative Identification of asbestos
andthesemi-quantitativedeterminationofasbestoscontenfofbulksamples, expressed as a percentage of the protected area. Quantitation of asbestos content was .
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
simitar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 3 of 3