JLC ENVIRONMENTAL CONSULTANTS. INC.
290 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax; (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code; 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and ALHA Lab Code: 100273
Date Received; 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B38S
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
DATE ASBESTOS TOTAL % OF CONSTITUENTS
DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
4005 4th Floor/ South East/ Floor/ Sample of GRAY/ NO 0% CELL 20%
9/28/01 Debris WHITE FBGL 10%
11051 NFIB 70%
4-005
4006 4th Floor/ South East/ Floor/ Sample of GRAY NO 0% CELL 25%
9/28/01 Debris NFIB 75%
11052
4-006
4007 4th Floor/ South East/ Window/ Sample of GRAY NO Q% CELL 5%
9/28/01 Debris FBGL 25%
11053 NFIB 70%
4-007
4008 4th Floor/ South East/ Floor/ Sample of GRAY/ NO 0% CELL 15%
9/28/01 Debris WHITE FBGL 15%
11054 NFIB 70%
4-008
•INSUFFICIENT MATERIAL SUBMITTED •TEM RECOMMENDED •“NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL’Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM. Model BH-2A/M Stereomicroscope, Model
VMZ 1x-4x. GulamMachhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This “Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limiled to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was.
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other liberswith optical properties similar to asbesSo
may give positive interferences and will be considered asbestos under this methodology. Also. PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quanlitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbesfos containing.
Page 2 of 3
CITY_21MC100_011914159
NYC-WTC_000357474