NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

PLM asbestos analysis, NYC site, Sept 2001

Machine-extracted title · confidence 42%

Summary of analytical results for asbestos by PLM for a NYC site, Sept 2001.

NYC-WTC_000357476–000357478
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 ParkAvenue South, Suite 1001, New York, New York 10003 Phone; (212) 420-8119 Fax: (212) 420-6092 Project No.: 01-2102 Metcalf & Eddy Inc. ELAP Lab Code: 11029 Analyte; ASBESTOS 3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273 Date Received: 9/28/01 Lebanon, NJ 08833 NVLAP Lab Code 101953 Date Analyzed: 9/29/01

SUMMARY OF ANALYTICAL RESULTS - PLM BatcH#: 0109B385

Site; 3 World Financial Center - Floors 3-26

SAMPLE # ASBESTOS TOTAL % OF CONSTITUENTS DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS COLLECTED LAB*

CLIENT'S SAMPLE #

6009 6th Floor/ South East/ East Wall - Deks/ GRAY NO 0% fbgl 20% 9/28/01 Sample of Debris NFIB 80% 11035 6-009

’INSUFFICIENT MATERIAL SUBMITTED ’TEM RECOMMENDED ’•’NOT ANALYZED POSITIVE STOP

ASBESTOS CONSTITUENTS NQN-A5BESTOS CONSTITUENTS Sample Analysis by. Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber AMOS = Amosite Asbestos MINW = Mineral Wool CROC = Crocidolite Asbestos FBGL = Fiberglass Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers Al' samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose "Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous USEPA/600/R-93/116, July 1993. ORGM = Organic Material WOLL = WoBastonile Instrumentation: HSHR = Horse Hair OTHR = Other Olympus PLM, Model BH-2A/M Stereomicroscope, Model VMZ 1x-4x, Gulam Machhiwala Laboratory Director

Analytical results reflect the makeup of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte . approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to ‘ samples containing large amounts ot fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was determined with a visual volume eslitnate, a calibrated visual area estimafe, and/or point counting procedure. CAUTION; Other fibers with optical properties similar to asbesto may give positive interferences and will be considered asbestos under Ibis methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b considered or treated as non-asbestos containing..

Page 3 of 3

CITY_21MC100_011914166

NYC-WTC_000357478

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357478Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →