NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, NewYork 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab CorJe: 11029
Analyte; ASBESTOS
3 Werner Way, Suite 310 NIOSH and aIHA Lab Code: 100273
Date Received: 9/29/01
Lebanon, NJ 08833 NVLAP Lab Code; 101953
Date Analyzed: 9/29/01
Batch #: 0109B386
SUMMARY OF ANALYTICAL RESULTS - PLM
Site; 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE#
20001 20th Floor/ Area of Damage/ South East BROWN NO 0% CELL 20%
9/27/01 Corner of Building/ Sample of Debris FBGL 20%
11107 NFIB 60%
20-001
20002 20th Floor/ Area of Damage/ South East BEIGE NO 0% CELL 10%
9/27/01 Corner of Building/ Sample of Debris NFIB 90%
11108
20-002
20003 20th Floor/ Area of Damage/ South East BROWN NO 0% CELL 25%
9/27/01 Corner of Building/ Sample of Debris FBGL 20%
11109 NFIB 55%
20-003
20004 20th Floor/ Area of Damage/ South East BROWN/ NO 0% CELL 40%
9/27/01 Corner of Building/ Sample of Debris WHITE FBGL 15%
11110 NFIB 45%
20-004
"INSUFFICIENT MATERIAL SUBMITTED “TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized LigM Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sampto Preparation and Analvstsi ACTN = Actinolite Asbestos SYNF= Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
■Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anlhophylite Asbestos ' NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model /?T Yr
VMZ1X-4X. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
■ approval of JLC Laboratory, and it must not be used by clienl to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to ■
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar Io asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestcs in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 1 of 3
CITY_21MC100_011914203
NYC-WTC_000357503
OCR can misread numbers and units. Confirm readings against the page image before using them.