NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 681 pages

Chain of custody log, DOT materials, 1998

Machine-extracted title · confidence 52%

Codified records of documents and custody in DOT files.

NYC-WTC_000355074–000355754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

§38.159 49 CFR Subtitle A (10-1-98 Edition)

sufficient clearances to permit a wheel- while occupied (i.e., "rotary lift"), the chair or other mobility aid user to requirements of this paragraph (b)(2) reach a securement location. At least prohibiting the lift from being stowed two securement locations and devices, while occupied shall not apply if the complying with paragraph (d) of this stowed position is within the passenger section, shall be provided. compartment and the lift is intended (2) Exception. If portable or station- to be stowed while occupied. based lifts, ramps or bridge plates (3) Emergency operation. The lift shall meeting the applicable requirements of incorporate an emergency method of this section are provided at stations or deploying, lowering to ground level other stops required to be accessible with a lift occupant, and raising and under regulations issued by the Depart- stowing the empty lift if the power to ment of Transportation, the bus is not the lift fails. No emergency method, required to be equipped with a vehicle- manual or otherwise, shall be capable borne device. of being operated in a manner that (b) Vehicle lift—(1) Design load. The could be hazardous to the lift occupant design load of the lift shall be at least or to the operator when operated ac- 600 pounds (2665 N). Working parts, cording to manufacturer's instructions, such as cables, pulleys, and shafts, and shall not permit the platform to be which can be expected to wear, and stowed or folded when occupied, unless upon which the lift depends for support the lift is a rotary lift and is intended of the load, shall have a safety factor to be stowed while occupied. of at least six, based on the ultimate (4) Power or equipment failure. Plat- strength of the material. Nonworking forms stowed in a vertical position, and parts, such as platform, frame and at- deployed platforms when occupied, tachment hardware which would not be shall have provisions to prevent their expected to wear, shall have a safety deploying, falling, or folding any faster factor of at least three, based on the than 12 incheslsecond (305 mm/sec) or ultimate strength of the material. their dropping of an occupant in the (2) Controls—U) Requirements. The event of a single failure of any load controls shall be interlocked with the carrying component. vehicle brakes, transmission, or door, (5) Platform barriers. The lift platform or shall provide other appropriate shall be equipped with barriers to pre_ mechanisms or systems, to ensure that vent any of the wheels of a wheelchair the vehicle cannot be moved when the or mobility aid from rolling off the lift is not stowed and so the lift cannot platform during its operation. A mov- be deployed unless the interlocks or able barrier or inherent design feature systems are engaged. The lift shall de- shall prevent a wheelchair or mobility ploy to all levels (i.e., ground, curb, aid from rolling off the edge closest to and intermediate positions) normally the vehicle until the platform is in its encountered in the operating environ- fully raised position. Each side of the ment. Where provided, each control for lift platform which extends beyond the deploying, lowering, raising, and stow- vehicle in its raised position shall have ing the lift and lowering the roll-off a barrier a minimum 1V inches (13 mm) barrier shall be of a momentary con- high. Such barriers shall not interfere tact type requiring continuous manual with maneuvering into or out of the pressure by the operator and shall not aisle. The loading-edge barrier (outer allow improper lift sequencing when barrier) which functions as a loading the lift platform is occupied. The con- ramp when the lift is at ground level, trols shall allow reversal of the lift op- shall be sufficient when raised or eration sequence, such as raising or closed, or a supplementary system lowering a platform that is part way shall be provided, to prevent a power down, without allowing an occupied wheelchair or mobility aid from riding platform to fold or retract into the over or defeating it. The outer barrier stowed position. of the lift shall automatically raise or (ii) Exception. Where the lift is de- close, or a supplementary system shall signed to deploy with its long dimen- automatically engage, and remain sion parallel to the vehicle axis and raised, closed, or engaged at all times which pivots into or out of the vehicle that the platform is more than 3 inches

536

NYC-WTC 000355619

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355619Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →