NYC 9/11 Public Portal Document

lA&SJ Information lli£S£J.ToBuildOn £ngfn9crlny • C^natMin^ •

October 2,2001

Mr. Niles Miller Dormitory Authority State of New York One Penn Plaza, 52“* Floor New Yoik, NY 10119

Subject: Environmental Testing Results Borough of Manhattan Community College 199 Chambers Street ■ New York, NY....... ........ - pgj ProjWNTiraBejTt?224-A139"=^-'^^-^----

Dear Mr. Miller;

At the request of the Donnitory Authority State of New York, Professional Service Industries, Inc. (PSI) performed environmental testing al the subject facility on September 28 and September 29, 2001. PSI performed a walkthrough of the facility on Friday September 21, 2001. The purpose of our walkthrough was to perform a visual inspection and develop an appropriate sampling strategy.

Results of all air and surface testing for asbestos, lead, silica, and dust are below the established regulatory or guideline levels for the selected analyte, Please find a summary of our testing results below.

Asbestos in Air PSI collected 3 representative air samples from each floor of the north and south buildings. In addition, 3 samples were collected from within the Gymnasium (north building) and Theater I (south building) as these areas were subject to use by emergency/rescuc workers. A total of 48 air samples were collected. Samples were collected and analyzed by Transmission Electron Microscopy in accordance with EPA 40 CFR Part 763 Final Rule (AHERA). AHERA regulations establish the post abatement air clearance criteria for asbestos abatement projects performed within schools (Grades K- 12). The AHERA post asbestos abatement clearance criteria is defined as an airborne asbestos fiber concentration less than 70 structures per millimeter squared (<70 s/mm2). The samples collected are not intended to be post abatement clearance samples, and the results have been compared to the established AHERA criteria for the purposes of referencing an established regulatory limit.

Laboratory analysis found no asbestos fibers present in 46 of the 48 samples collected. Asbestos was detected in the following 2 locations however, the airborne asbestos concentrations are below the established AHERA post abatement clearance criteria.

Prolessional Service Industries, Inc. ■ fl East 37ih Street. 11th Floor-New Ycrk Chy. NY 10018 • Pnone 212/889-0264 ‘rex 2i2/6fl8-04M

I 200a iCi'ON

CITY_21MC100_008942345

NYC-WTC_000353994

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353994Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →