Z Z o fr o ATTACHMENT 2 co

§ '2 o o WTC Indoor Air Monitoring - Sampling and Analytical Procedures ■D c CT o' Ca5 ■D OO o OO Analytical 3. O Media Sampling Points Sampling Method Proposed Sampling Vulnersbility/Practicality Analytical Method Proposed 91 Parameters O o o Carpets, fabric furniture or c SeHled drapery in areas of activity This is a micro vacuuming method. Three collocated samples will 3 Dust Asbestos ASTM D 5755-95 ASTM D 5755-95 CD (living rooms, family be collected from each location. Porous ___ rooms) Soft surfaces Lead This is a micro vacuuming method. Three collocated samples will ASTM E 1973-99 SW-846 6010B be collected from each location.

Horizontal surfaces of tables or counters and Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe) bare floors, ceilings and walls in areas of activity /living rooms, family rooms) Lead ASTME 1728 Wipe Samples SW-846 601 OB Settled Dust Non-porou Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 s Hard surfaces PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C

Silica ASTME 1728*’ Wipe Samples NIOSH 7500 (XRD)

MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

Areas of known activity Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA /living rooms, family Asbestos wkgroup detection limits method. ----- roems)------------ Air pi rrip operated at lOL/min for 8 hours to achieve the COPC Leac J wkgroup detection limits SW-846 601 OB 7^ C.. ”__ i 'ei iOme- PAHs requirements and to account for Pilot clean-up study only SW-846 8270 break through on the cassettes. Indoor Air TBD Pending sample volume o Pilot clean-up study only. Availability of sample cassettes for Dioxins requirements and to account for SW-846 8290 dioxins analysis is questionable. Apparently the supply is low. break through on the cassettes. K I Air pump operated at 2.5L/min for 8 hours to achieve the COPC Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits

Assumed that it behaves the same as asbestos, samples will be o MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling. o I o NOTE; All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh o the sample wipe or cassette prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust. to ** Silica will be collected as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF. '.c co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348870Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348854

Proposed parameters and study design for WTC environmental sampling.

Similar indexed content

Compare copies and versions →