NYC 9/11 Public Portal Document EfiX NO, 212 7B8 lfc>4U H. u//ia Hr AnHlkNT GHGIH INC

ambient group i„c. maik’Nai buAnotiARnas

55 WIST snujxT Indoor environmontaJ qualicy sirrvoys jx»h noon Water treatment consulting NVW YOnK, NEW YOHK ««uS Aibostos &. lead field services TGU (3UJ ^Ch-'/Ri^ Regulatory compliance programs fax; {Jill A»r, water & soil analytical laboratones WT-H: www,AMiiu.NrGRCtJ!‘.rn 4

October 22, 2001

Mr. Elliot Zuckerman Cushman & Wakefield a/a/f Mercantile Exchange One North End Avenue New York. New York 10282

Re; One North End Avenue Ambient Project # 211338

Dear Mr. Zuckcrmen:

The following is a si^maxy of the indoor environmental quality survey that Ambient Group, Inc. performed on September IS’”, 2001 at the above referenced location. The survey included sampling for airborne metals, carbon dioxide, carbon monoxide, temperature, relative humidity, polynuclear aromatic hydrocarbons and airborne asbestos structures by TEM.

Analysis of all indoor readings for carbon dioxide and carbon monoxide revealed that all indoor readings were below OSflA, ACGIH, ASHRAE and other recommended industry guidelines and/or regulations.

The indoor temperature readings ranged from 66.O”F to 69,6 F. The indoor relative humidity roadings ranged from 53,4% to 60.7%, All indoor relative humidity readings were consistent with the conditions described in the ASHRAE 55-1992 thermal comfort standard as well as ideal indoor conditions. Tire indoor temperature readings were slightly below the ASHRAE 55-1992 thermal standard for fall/winter months (69’F - 76°F).

Four (4) TEM samples were collected from floors 3, 7, 11 and from the lobby and analyzed by transmission electron microscopy (TEM) for asbestos structures. The results of the analysis indicated that airborne asbestos levels inside and outside the building at the time of testing were less than the analytical sensitivity of the instrument, which is well below the EPA standard of 70 structures/mm’ as well as other recommended industry guidelines and/or regulations.

Four (4) air samples were collected from floors 3, 7, 11 and from the lobby and analyzed for polynuclear aromatic hydrocarbons in air. Analysis of all four (4) samples collected revealed that the levels of the individual compounds were below the OSHA Permissible Exposure Limits and NIOSH REI/ guidelines.

cunCAGO, ir. OKANGIv, CA tn r,N fuvjs. ny IT 96 Cco-iHinQ szz-s'ii^ 7»/^

10/22/01 MON 17:05 ITl/RX NO 8257]

CITY_21MC100_003003561

NYC-WTC_000342947

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342947Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →