Bulk sampling and TEM monitoring, Building 100

Machine-extracted title · confidence 40%

ALC bulk sampling and TEM air monitoring for Building 100, Oct 2001.

NYC-WTC_000342682–000342683
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OPPOnATED TAL The First Choice for Environmental Testing & Consultin

October 22. 2001

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280

Subject: Gateway Plaza Building #100

Gentlemen;

ALC Environmental Incorporated (ALC) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project. Every apartment in the building was assessed by our inspectors for dust and debris. Any area where visible dust and debris was found, ALC’s inspectors took a bulk sample, which was then sent to a third party independent laboratory for analysis. In most cases there was insufficient debris to sample and a visual assessment only was performed. Additionally, air sampling was performed using TEM Methodology on every floor in the building.

Eight (8) initial background air samples were collected and analyzed at building 100. Eight (8) were analyzed via phase contrast microscopy (PCM) and five (5) were analyzed via transmission electron microscopy (TEM). After analysis via TEM, all were below the permissible limits.

Based on EPA Guidelines, we collected forty (40) bulk samples and analyzed them via Polarized Light Microscopy (PLM) Methodology. ZeroJOLwere found to be above the regulatory limits

ALC then collected air samples on every floor in the building. The air sampling and analysis was done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE fl AHERA7ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

Twenty-nine (29) air samples were collected and analyzed via TEM Methodology. The results indicated that the living areas achieved the acceptance criteria below <70 structures per mni2 set by the above regulations.

West 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax: 212.279.6747 'fficc; The Bellevue • Suite 600 • 200 S. Broad Street • Philadelphia, PA 19102 • 215.732.9499 • 898.789,8378 • Fax; 215.732.955- www.ALCEnvi ronmental. com

CITY_DEP_WORBY_CANNATA_SUBP_000006527

NYC-WTC_000342682

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342682Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342625

Correspondence about bulk sampling, visual assessments, and air monitoring at Building #500.

Similar indexed content

Compare copies and versions →