Final Air Monitoring Report, Building #200

Machine-extracted title · confidence 39%

Subject: final air monitoring report after asbestos cleanup at Building #200.

NYC-WTC_000342627
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document OCT-05-2001 12:00 p.02 i

luf i 1

OMHOfmamL iMconinfintTeB The First Choice for Environmental Testing & Consulting

NYCDEP Mr, JCrLsh Radhakrishnan, P,E, Director 59-17 Junction Doulevird. 8“' Floor Corona, NY 11368-3107 ViAFafiSjgiilc 'y'a; '■'6

Subject; Final Air Clearance Samatlng: Gateway Piwa 3S5 Southend Avenue BuildinE 200; ’.■i' ' At>artn>ertes.23F. 22F, 34D, lOH, 17B, IdF

Pear Mr. Radhaki'ishnan, P.E.

Please find enclosed the third party air monitoring report performed at selected locations of the above rcfeienced location. Upon completion of the asbestos clean up procedures, a visual inspection was conducted in the work areas located i.n the in the specific apartments of the 20C building of the Gateway Plaza. Since no visible asbestos containing material (acm) or debris was seen, final air clearance santpiittg WAS then conducted.

The sir sampling tad analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 192638) EPA HESHAP5 (40 CFR PART 61), AND TSCA TITLE II AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Enviroiunemal Protection Title 15 Asbestos Regulatioiis.

The air sanipies were collected by Alvin B. Blake a licensed sampling technician (AH#0L03528) under the supervision of Ainetico Rodriguez Jr., a licensed project monitor (AH# 89-07160) 4>' ATC Assoeiaies (SLAP #10879) analyzed the sampies using the Transmission Electron Microscopy (TEM) Methodology, The i^ults indicated that the work areas achieved the accentantc criteria of at vr below <0.01 fibers per cubic ceotiiweters set bv the above regulations <3 If you have any qucsliowt and/oi comments please conucl us ditectly al 212 279.10(51

Sinewy,

mua Sarett ,C Environmental inc. 7" Cc Richard Letrak, Charles Mehlman

115 Wes! 30th Street • llth Floor • New York, New York 1001)1 ♦ 212.279,1001 • 888,466 3620 » Fax: 212.279,6747 IJomi- trnVe; The Bellevue < Soiic 500 • 200 S. Broad Strew ‘ Philadelphia, PA 19102 ” 215.732.9499 • 888.739.6378 » Fax: 215,732 9559 www.ALCF-iivironmeiUfll com

CITY_21MC100_0 02990560

NYC-WTC_000342627

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342627Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342636

Final air monitoring report enclosed; clearance inspection following asbestos cleanup.

Similar indexed content

Compare copies and versions →