NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
12 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗Preliminary data on VOCs, PCBs, PAHs and hazardous substances from WTC sampling.
NYC-WTC_000340929–000340933OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
DSN Monthly Average Long Term Average Description of Flow, GPD (Appl) Flow, GPD (DMR) Treatment
001 7200 480 None
002 32000 480 None
003 NA NA None
Parameter Non-numeric Monitoring Requirements Effluent Limit Frequency Type
Flow(GPD) BMP Semi-Annually Calculated
pH BMP Semi-Annually Grab TSS, mg/L TOC, mg/L Petroleum Hydrocarbons, mg/L
Preliminary Results:
Metals: Laboratory results fur metals and a comparison with results from runoff, ambient, and Newtown Creek STP samples are shown in Table 1. Toxic metals were not detected, except for barium which was detected at an elevated concentration versus the ambient Hudson River background sample collected on 09/20/01 by the George Washington Bridge. The barium concentration of 150 ug/L is less than the 1000 ug/L federal ambient water criteria for protection of human health from carcinogens, the only federal water quality criteria for this metal. Calcium, iron, and manganese were detected at elevated concentrations relative to GWB background, and sodium and potassium were detected at lower values. No other metals were detected.
PCS Congeners : None of the 71 PCB congeners analyzed were detected (DL 0.0054 ug/L).
NVOAs: Thirteen NVOA compounds were detected. Ten of these NVOAs are PAHs. There are neither federal marine acute or chronic criteria for any of the detected NVOAs. Benzoic acid (500 ug/L) and bis-2(chloroisopropyl) ether (69 ug/L), and 2,4-dimethyl phenol were detected at the highest concentrations. These compounds are not PAHs, which were detected a very low concentrations.
VOCs: Seven (7) VOCs were detected, all at less than 100 ug/L. For the detected VOCs, federal marine Water Quality Criteria are only applicable for toluene, with acute and chronic marine criteria of 6300 and 5000 ug/L, respectively. Toluene was detected at 13 ug/L, far below the criteria concentrations. Table 2 provides
CITY_21MC100_009262438
NYC-WTC_000340930
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
12 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
12 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
18 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209168
Document excerpt listing laboratory results for volatile organic compounds, total petroleum hydrocarbons, and asbestos in water samples.
7 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432199
Preliminary dewatering discharge sampling results; various contaminants and comparatives.
17 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
17 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
18 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302159
Preliminary data for WTC area sampling across VOCs, PCBs, PAHs, metals, and asbestos; PATH tunnel permit noted.
11 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304415
Preliminary results for VOCs, PCBs, PAHs, metals and asbestos from PATH-related sampling.
11 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241840
Preliminary bulk and VOC sampling data near WTC debris and Hudson River discharge.
11 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307523
PATH dewatering sample results; toxicity and BOD summary for WTC tunnel-related testing.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302162
Metals results and water sampling data for PATH tunnel discharge and Hudson River locations.
6 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000209168
Document excerpt listing laboratory results for volatile organic compounds, total petroleum hydrocarbons, and asbestos in water samples.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304415
Preliminary results for VOCs, PCBs, PAHs, metals and asbestos from PATH-related sampling.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241840
Preliminary bulk and VOC sampling data near WTC debris and Hudson River discharge.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302159
Preliminary data for WTC area sampling across VOCs, PCBs, PAHs, metals, and asbestos; PATH tunnel permit noted.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
Similar indexed content
NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
Similar indexed content
NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
Similar indexed content
NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
Similar indexed content
NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
Similar indexed content