NYC 9/11 Public Portal Document
Parameter Non-numeric Monitoring Requirements
Effluent Limit Frequency Type
Flow (GPD) BMP Semi-Annually Calculated
pH BMP Semi-Annually Grab
TSS, mg/L
TOC, mg/L
Petroleum
Hydrocarbons, mg/L
Preliminary Results:
Metals: Laboratory results for metals and a comparison with results from runoff, ambient,
and Newtown Creek STP samples are shown in Table 1. Toxic metals were not
detected, except for barium which was detected at an elevated concentration
versus the ambient Hudson River background sample collected on 09/20/01 by the
George Washington Bridge. The barium concentration of 150 ug/L is less than the
1000 ug/L federal ambient water criteria for protection of human health from
carcinogens, the only federal water quality criteria for this metal. Calcium, iron,
and manganese were detected at elevated concentrations relative to GWB
background, and sodium and potassium were detected at lower values. No other
metals were detected.
PCB Congeners : None of the 71 PCB congeners analyzed were detected (DL 0.0054 ug/L).
NVOAs: Thirteen NVOA compounds were detected. Ten of these NVOAs are PAHs.
There are neither federal marine acute or chronic criteria for any of the detected
NVOAs. Benzoic acid (500 ug/L) and bis-2(chloroisopropyl) ether (69 ug/L), and
2,4-dimethyl phenol were detected at the highest concentrations. These
compounds are not PAHs, which were detected a very low concentrations.
VOCs Seven (7) VOCs were detected, all at less than 100 ug/L. For the detected VOCs,
federal marine Water Quality Criteria are only applicable for toluene, with acute
and chronic marine criteria of 6300 and 5000 ug/L, respectively. Toluene was
detected at 13 ug/L, far below the criteria concentrations. Table 2 provides
laboratory results for the detected VOCs.
Total Petroleum Hydrocarbons: (TPH): TPH was not detected (DL 5 mg/L).
Total Organic Carbon: (TOC): TOC was detected at 73 mg/L. There is no criteria for this
parameter.
>)
CONFIDENTIAL, CITY_21MC100_009513682
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000241841
OCR can misread numbers and units. Confirm readings against the page image before using them.