Parameter Non-nuraeric Monitoring Requirements Effluent Limit Frequency Type

Flow (GPD) BMP Semi-Annually Calculated

pH BMP Semi-Annually Grab TSS, mg/L TOC, mg/L Petroleum Hydrocarbons, mg/L

Preliminary Results:

Metals: Laboratory results for metals and a comparison with results from runoff, ambient, and Newtown Creek STP samples are shown in Table 1. Toxic metals were not detected, except for barium which was detected at an elevated concentration versus the ambient Hudson River background sample collected on 09/20/01 by the George Washington Bridge. The barium concentration of 150 ug/L is less than the 1000 ug/L federal ambient water criteria for protection of human health from carcinogens, the only federal water quality criteria for this metal. Calcium, iron, and manganese were detected at elevated concentrations relative to GWB background, and sodium and potassium were detected at lower values. No other metals were detected.

PCB Congeners ; None of the 71 PCB congeners analyzed were detected (DL 0.0054 ug/L).

NVOAs: Thirteen NVOA compounds were detected. Ten of drese NVOAs are PAHs. There are neither federal marine acute or chronic criteria for any of the detected NVOAs. Benzoic acid (500 ug/L) and bis-2(chloroisopropyl) eitier (69 ug/L), and 2,4.-dimethyl phenol were detected at the highest concentrations. These compounds are not P.\Hs, which were detected a very low concentraUons.

VOCs: Seven (7) VOCs were detected, all at less than 100 ug/L. For the detected VOCs, federal marine Water Quality Criteria are only applicable for toluene, with acute and chronic marine criteria of 6300 and 5000 ug/L, respectively. Toluene was detected at 13 ug/L, far below the criteria concentrations. Table 2 provides laboratory results for the detected VOCs.

Total Petroleum Hydrocarbons: (TPH): TPH was not detected (DL 5 mg/L).

CITY_21MC100_003113130

NYC-WTC_000304416

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304416Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Laboratory results for VOCs and asbestos

NYC-WTC_000209168

Document excerpt listing laboratory results for volatile organic compounds, total petroleum hydrocarbons, and asbestos in water samples.

Similar indexed content

Compare copies and versions →