NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
12 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗Preliminary data on VOCs, PCBs, PAHs and hazardous substances from WTC sampling.
NYC-WTC_000340929–000340933OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
laboratory results for the detected VOCs.
Total Petroleum Hydrocarbons: (TPH): TPH was not detected (DL 5 mg/L).
Total Organic Carbon: (TOC): TOC was detected at 73 mg/L. There is no criteria for this parameter.
Non-Filterable Residue (TSS): TSS was reported at 26 mg/L, which is less than the 33 mg/L detected in effluent from the Newtown Creek STP.
BODS (mg/L): The BOD5 was reported as 69 mg/L. This is less than the 09/15-16/01 Newtown Creek STP influent of 210 mg/L, and less than two times greater than the Newtown Creek STP effluent of 38 mg/L.
Asbestos: Asbestos was reported as <2.61 MFL. The drinking water MCL is 7 MFL.
Dioxins/Furans: OCDD (0.0307 J ng/L) and 1234678 TCDF (0.0051 J ng/L) were detected. The total TEQ for the sample is is 0.0014 ng/L calculated with non detects at 54 the detection limit.
CITY_21MC100_009262439
NYC-WTC_000340931
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
12 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
12 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
18 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209168
Document excerpt listing laboratory results for volatile organic compounds, total petroleum hydrocarbons, and asbestos in water samples.
7 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432199
Preliminary dewatering discharge sampling results; various contaminants and comparatives.
17 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
17 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
18 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302159
Preliminary data for WTC area sampling across VOCs, PCBs, PAHs, metals, and asbestos; PATH tunnel permit noted.
11 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304415
Preliminary results for VOCs, PCBs, PAHs, metals and asbestos from PATH-related sampling.
11 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241840
Preliminary bulk and VOC sampling data near WTC debris and Hudson River discharge.
11 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307523
PATH dewatering sample results; toxicity and BOD summary for WTC tunnel-related testing.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302162
Metals results and water sampling data for PATH tunnel discharge and Hudson River locations.
6 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000209168
Document excerpt listing laboratory results for volatile organic compounds, total petroleum hydrocarbons, and asbestos in water samples.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304415
Preliminary results for VOCs, PCBs, PAHs, metals and asbestos from PATH-related sampling.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302159
Preliminary data for WTC area sampling across VOCs, PCBs, PAHs, metals, and asbestos; PATH tunnel permit noted.
Similarity score 0.973 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241840
Preliminary bulk and VOC sampling data near WTC debris and Hudson River discharge.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000432102
Final preliminary data for World Trade Center sampling; DOS project summary.
Similar indexed content
NYC-WTC_000432195
Final preliminary data from NYC World Trade Center sampling; VOCs, PCBs, PAHs, metals, etc.
Similar indexed content
NYC-WTC_000340934
Preliminary results for dewatering samples around PATH location, VOCs and PAHs detected.
Similar indexed content
NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
Similar indexed content
NYC-WTC_000307428
Preliminary results for dioxins, furans, asbestos, and BOD at WTC dewatering sample.
Similar indexed content