NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Asbestos air sampling results summary, 12/22/01

Machine-extracted title · confidence 32%

OSHA asbestos air monitoring summary with total samples, zones, PCM/TEM results and exposure levels.

NYC-WTC_000340068–000340069
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Oxides jf .Nitrogen/ Sulfur: Sampling on grappler operators on the rabble pile, and on employees .Tinning truck wash stations revealed trace levels of nitnc oxide and nitrogen dioxide. lO; personal and area results were founo to he below OSHA limits.

Metals: CSFIA has taken 653 air samples to monitor worker expcsure.s to dusts, Ones, oxides, and other compounds of metals such as antimony, berdhum. chromium, cioalt. copper. iron, lead, manganese, molybdenuir., nickel, vanadium, zine, cadmium, magnesium, arsenic, and mcrcur/. Results from these samples are generaily well below the applicable OSH.A limius. However, torch cutting and burning stmeturai steel at the nibble pile have resulted in instances of overexposures as follows: coppu (10); iron o.xide (-1); lead (12); and cadmium (2). .Accordingly, OSHA is recomr.ending that workers engaged in these operations wear appropriate respiratory protection.

lonizino Radiation: A survey of'.he rabble pile was conducted on 10/22-10,'23 to check for latent radiation with particular attention to alpha radiation. Preliminary results show no elevated levels.

Diovins: OSHA has taken samples for dioxin and these samples were analyzed byEPA. One initial sample, representing exposure directly on the pile, showed elevated levels of dioxins when compared to ambient background levels. This value was comparable to the levels fo.ind by EP A sampling. The dioxins at this location are being emitted from the on-aoing rabble fire. Additional sampling was conducted around the penmeter of the pile and revealed levels that were considerably lower than those on the rubble pile. Dioxins are considered collectively as ,s'j,speci human carcinogens. OSH.A does not have a worker standard for dioxins. OSH.A is coordinating with EPA, and the Salt Lake City Analytical Laboratory to fully assess the nsk posed by the elevated levels of dioxins. Polyauciear Aromatic Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons.' anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified seven samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2ing/m'. These persona! samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respirator/ protection when working on the rubble pile. Freon R-22, Hydrogen Fluoride & Ptiosgcne; OSHA has taken 105 samples for Freon L-22 (chlorodiTouromethane). The majonty of sample results received to December 1 reveal non-detectable airborr.e levels. During operations involving Freon removal from the auxiliary chiller that started on 12/5/01, direct reading instrument revealed readings ranging from 100 ppm to one peak near a leaky valve of 500 ppm. SCBA tank.s were and are being worn by workers, and naasks are to be worn only when direct reading instruments reveal 850 ppm Freon and/or less than 20.433 Oxygen. OSHA does not have an exposure limit for Freon R-22. (The NIOSHREL for Freon is lOCOppm..) In response to information about e.xposure to the decomposition by-products of Freon R-22 used in the air conditioning systems ofWTC towers, sampling tor hydrofluoric acid (HF) had been conducted. Results for HF revealed r.on-detectable levels. Sample results for phosgene to date show non- deteciable levels.

Page 2 of 2

CITY_21MC100_007231249

NYC-WTC_000340069

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340069Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000302117

OSHA asbestos and noise sampling summary for World Trade Center rubble pile and surrounding areas.

Similar indexed content

Compare copies and versions →