NYC 9/11 Public Portal Document
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees minning truck
wash stations revealed trace levels of nitric oxide and nitrogen dioxide. >0; persona!
and area results were found to be below OSHA limits.
Metals: OSHA has taken 653 air samples to monitor worker exposures to dusts, fumes, oxides,
and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper,
iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium,
arsenic, and mercury. Results from these samples are generally well below the
applicable OSHA limits. However, torch cutting and burning structural steel at the
rubble pile have resulted in instances of overexposures as follows: copper (10); iron
oxide (21); lead (12); and cadmium (2). Accordingly, OSHA is recommending that
w’orkers engaged in these operations wear appropnate respiratory protection.
Ionizing Radiation A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation
with particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed by EPA. One
initial sample, representing exposure directly on the pile, showed elevated levels of
dioxins when compared to ambient background levels. This value was comparable to
the levels found by EPA sampling. The dioxins at this location are being emitted from
the on-gomg rubble fire. Additional sampling was conducted around the penmeter of
the pile and revealed levels that were considerably lower than those on the mbble pile.
Dioxins are considered collectively as suspect human carcinogens. OSHA does not
have a worker standard for dioxins. OSHA is coordinating with EPA, and the Salt
Lake City Analytical Laboratory to fully assess the nsk posed by the elevated levels of
dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 132 samples. The majonty of the samples have not shown the
presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic
hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample
results to date have identified seven samples which reached or exceeded OSHA’s coal
tar pitch volatile PEL of 0.2mg/m'’. These personal samples were taken on the pile on
iron workers and grappler operators. OSHA continues to strongly recommend the use
of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken 105 samples for Freon R-22 (chlorodiflouromethane). The majonty of
sample results received to December 17'*' reveal non-detectable airborne levels. During
operations involving Freon removal from the auxiliary chiller that started on 12/5/01,
direct reading instrument revealed readings ranging from 100 ppm to one peak near a
leaky valve of 500 ppm. SCBA tanks were and are being worn by workers, and masks
are to be worn only when direct reading instruments reveal 850 ppm Freon and or less
than 20.4% Oxygen. OSHA does not have an exposure limit for Freon R-22. (The
NIOSH REL for Freon is lOOOppm..) In response to information about exposure to the
decomposition by-products of Freon R-22 used in the air conditioning systems of WTC
towers, sampling for hydrofluonc acid (HF) had been conducted. Results for HF
revealed non-detectable levels. Sample results for phosgene to date show non-
detectable levels.
Page 2 of 2
CITY_21MC1OO_OO653523O
NYC-WTC_000361370