NYC-WTC_000304583
Summary of asbestos air monitoring results across financial district and rubble pile areas.
26 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗OSHA asbestos sampling results summary up to 12/22 for WTC rubble area.
NYC-WTC_000317838–000317839OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Oxides uf Nitrogen/ Sulfur: Sampling on grappler operators on the rubble pile, and on employees iranning truck wash stations revealed trace levels of nitnc oxide and nitrogen dioxide. SO: personal and area results were found to be below OSHA limits.
Metals: OSHA has taken 653 air samples to monitor worker exposures to dusts, fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury. Results from these samples are generally well below the applicable OSHA limits. However, torch cutting and burning structural steel at the mbble pile have resulted in instances of overexposures as follows: copper (10); iron oxide (21); lead (12); and cadmium (2). Accordingly, OSHA is recommending that workers engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed by EPA. One initial sample, representing exposure directly on the pile, showed elevated levels of dioxins when compared to ambient background levels. This value was comparable to the levels found by EPA sampling. The dioxins at this location are being emitted from the on-going rubble fire. Additional sampling was conducted around the perimeter of the pile and revealed levels that were considerably lower than those on the mbble pile. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a worker standard for dioxins. OSH.A. is coordinating with EPA, and the Salt Lake City Analytical Laboratory to fully assess the risk posed by the elevated levels of dioxins. Polynuclear Aromatic Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons; anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified seven samples which reached or exceeded OSHA's coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when working on the rubble pile. Freon R-22, Hydrogen Fluoride & Phosgene: OSHA has taken 105 samples for Freon R-22 (chlorodiflouromethane). The majority of sample results received to December 17^ reveal ncn-detectable airborne levels. During operations involving Freon removal from the auxiliary chiller that started on 12/5/01, direct reading instrument revealed readings ranging from 100 ppm to one peak near a leaky valve of 500 ppm. SCTL\ tanks were and are being worn by workers, and masks are to be worn only when direct reading instruments reveal 850 ppm Freon and/or less than 20.4% Oxygen. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) In response to information about exposure to the decomposition by-products of Freon R-22 used in the air conditioning systems ofWTC towers, sampling for hydrofluoric acid (HF) had been conducted. Results for HF revealed non-detectable levels. Sample results for phosgene to date show non- detectable levels.
Page 2 of 2
CITY_21MC1OO_OO2458298
NYC-WTC_000317839
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000304583
Summary of asbestos air monitoring results across financial district and rubble pile areas.
26 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302117
OSHA asbestos and noise sampling summary for World Trade Center rubble pile and surrounding areas.
26 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220267
A summary of OSHA sampling data regarding asbestos, lead, and noise levels on the World Trade Center rubble pile as of December 22, 2001.
26 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289801
OSHA PCM and TEM analyses report asbestos ambient air levels and personal samples in NYC debris work.
26 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199946
Summary of OSHA asbestos and diesel particulate monitoring results as of December 22, 2001, including exposure limits.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287798
OSHA monitoring results: asbestos counts, ppm levels, and rubble-pile exposure notes.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281857
OSHA PCM/TEM results from FDNY/financial district area; levels below PEL after analysis.
24 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205206
Summary of OSHA air monitoring results for asbestos, diesel exhaust, and noise exposure at the World Trade Center site as of December 22, 2001.
25 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388108
Summary of OSHA asbestos air samples collected in financial district rubble pile area.
26 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361369
OSHA asbestos sampling results summary; PCM, TEM analyses; results below or at limit.
26 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279845
OSHA asbestos sampling results and analysis, 12/22 update for rubble/financial district.
26 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000246756
OSHA sampling summary: asbestos, carbon monoxide, and noise monitoring on rubble pile.
25 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000302117
OSHA asbestos and noise sampling summary for World Trade Center rubble pile and surrounding areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199946
Summary of OSHA asbestos and diesel particulate monitoring results as of December 22, 2001, including exposure limits.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304583
Summary of asbestos air monitoring results across financial district and rubble pile areas.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220267
A summary of OSHA sampling data regarding asbestos, lead, and noise levels on the World Trade Center rubble pile as of December 22, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209199
OSHA report summarizing air sampling results for metal oxides, sulfur, nitrogen, and a radiation survey of the rubble pile conducted in October 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164098
Distribution of materials provided at January 15, 2002 WTC contractor health and safety meeting.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000304583
Summary of asbestos air monitoring results across financial district and rubble pile areas.
Similar indexed content
OSHA asbestos and noise sampling summary for World Trade Center rubble pile and surrounding areas.
Similar indexed content
A summary of OSHA sampling data regarding asbestos, lead, and noise levels on the World Trade Center rubble pile as of December 22, 2001.
Similar indexed content
NYC-WTC_000289801
OSHA PCM and TEM analyses report asbestos ambient air levels and personal samples in NYC debris work.
Similar indexed content
NYC-WTC_000199946
Summary of OSHA asbestos and diesel particulate monitoring results as of December 22, 2001, including exposure limits.
Similar indexed content