NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 12/22
Asbestos. A total of 910 air monitoring samples fcr asbestos nave been taken. From 9ri: -9, 21, 1’"
samples were taken in the financial district. They were taken on OSHArersonne! as
they walked within certain predetermined zones. Results reveaid asbestos
concentrations ranging trom ND (none detected; to .03’ Fee., well beliw OSHA's
permissible exposure limit (PEL) of. I fee. After 9 21, sampling focused in the nubble
pile and those workers working on or immediately next to it. 82 cf:he samples
a.nalyzed exceeded OSHA's limit via PCM analysis. Flowever. upon furiiier analysis
using discriminating counting methods and. or TEM analysis, the numbetof asbesto.s
ffeers found dropped dramatically to below detectable levels or well below .1 Fee.
Carbon Monoxide: A total of 77 persona! samples of workers on the rabble pile showed results ranging
from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure
limit.
>oise: OSHA has been conducting noise mcnitoring ;n the rubble pile. 41 personal samples
have been conducted on employees performing (or working near) various operations
such as jack hammcnr.g, drilling and equipment operations. Employees exposure to
the noise range from 73.7 dB A to 94.5 dBA. OSHA's permissible noise exposure for
construction is 90 dBA. One personal sample and one area sample duringcore drilling
operations exceeded the OSHA noise PEL of 90 dBA. OSHA continues to
recommend the use of appropriate hearing protection for workers performing tasks
where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majonty of the 408 silica samples show no detectable levels of
airborne silica. However, fourteen e.xposures e.xceeded the PEI.. The highest sample
result was approximately nine times the OSHA limit (pre-drillers working on the slurry
or “bathtub' wall). The other twelve elevated exposures were approximately one to
seven times the OSHA limit. These exposures occurred dunng: 1) rubble removal and
loading operations near the Winter Garden: 2) during the breaking up of concrete in
the pit; 3) while core drilling the concrete slurry wall, and 4) while chipping concrete
with power tools during demolition activities at 7 WTC's parlnng garaae. Most of the
work areas where apparent overexposures to silica occurred were in the nibble pile: an
area where OSHA continues to encourage the use of respiratory protection.
Volatile Organic
Compounds; OSHA has taken 608 samples for (VOCs) such as acetaldehyde, acrolein, aciylcnitnle,
benzene, 2-butanone. carbo furans, chlorodiphenyl (PCB). ethyl benzene, formaldehyde,
Freon R-22 (chlorodiflouromethane), hexone, i,socyanates (e,g, MDI, TDI),
perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl
chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated
levels of some organic chemicals resulting from the fires burning in the rubble pile.
Subsequent personal and area samples show worker e.xposure levels to be below
OSHA limits. However, one personal sample result for benzene was found to be at the
8-hr, OSFIA .Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris. See information below for polynuclear aromatics, Freon R-2-,
phosgene and dioxin.
Page 1 of 2
CITY_21MC100_007231248
NYC-WTC_000340068