OSHA SAMPLING RESULTS SUMMARY AS OF 12/22
Asbestos: A total of 910 air monitoring samples for asbestos have been taken. From 9/13 -9/21, 177
samples were taken in the financial district. They were taken on OSHA personnel as
they walked within certain predetermined zones. Results revealed asbestos
concentrations ranging from ND (none detected) to .037 f/cc., well below OSHA’s
permissible exposure limit (PEL) of. 1 f/cc. After 9/21, sampling focused on the rubble
pile and those workers working on or immediately next to it. 82 of the samples
analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis
using discriminating counting methods and/or TEM analysis, the number of asbestos
fibers found dropped dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging
from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure
limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal samples
have been conducted on employees performing (or working near) various operations
such as jack hammering, drilling and equipment operations. Employee's exposure to
the noise range from 73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for
construction is 90 dBA. One personal sample and one area sample during core drilling
operations exceeded the OSHA noise PEL of 90 dBA. OSHA continues to
recommend the use of appropriate hearing protection for workers performing tasks
where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 408 silica samples show no detectable levels of
airborne silica. However, fourteen exposures exceeded the PEL. The highest sample
result was approximately nine times the OSHA limit (pre-drillers working on the sluny
or “bathtub” wall). The other twelve elevated exposures were approximately one to
seven times the OSHA limit. These exposures occurred during: 1) rubble removal and
loading operations near the Winter Garden; 2) during the breaking up of concrete in
the pit; 3) while core drilling the concrete slurry wall, and 4) while chipping concrete
with power tools during demolition activities at 7 WTC’s parking garage. Most of the
work areas where apparent overexposures to silica occurred were in the rubble pile; an
area where OSHA continues to encourage the use of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 608 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, caibofurans, chlorodiphenyl (PCB), ethyl benzene, formaldehyde.
Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI),
perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl
chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated
levels of some organic chemicals resulting from the fires burning in the rubble pile.
Subsequent personal and area samples show worker exposure levels to be below
OSHA limits. However, one personal sample result for benzene was found to be at the
8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris. See information below for polynuclear aromatics. Freon R-22,
phosgene and dioxin.