NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 176 pages

Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mini-Monoqraph | Chemical analysis of WTC PM7 5

the composition of these samples with other numbers (1—13) on 12 September 2001, and diameter; Pail Gelman Sciences, Port well-studied PM2 5 reference samples. Solid letters (A-F) on 13 September 2001. After Washington, NY). Ten to 40 filters were samples of WTC and reference PM2.5 were examination of the available inventory of used in the size fractionation of each WTC analyzed by scanning electron microscopy samples, we selected seven locations (8, 11, sample. Roughly half the sample was in the (SEM), X-ray diffraction (XRD), X-ray fluo­ 13, B, C, E, and F) to assess toxicity of sam­ PM53-sieved fraction. About 80-89% of the rescence (XRF), carbon fraction analysis, and ples from different geographical locations as PM53 fraction was in the 10- to 53-pm size neutron activation analysis (NAA). Analyses well as overall toxicity of a pooled sample range, which is too large to use in respiratory were also carried out on water-extracted or from these locations (Figure 1). The locations toxicology studies, as deposition of particles 1 M hydrochloric acid-extracted suspensions were selected to represent a distribution sur­ > 5 pm is minimal in small laboratory animals of WTC and reference PM2.5. including rounding Ground Zero, with more collection (Raabe et al. 1988). The amount of the 2.5 to pH, endotoxin, and inductively coupled sites in the cast reflecting the direction of the 10-pm fraction was very small (0.04-1.14% of plasma-mass spectrometry (ICP-MS) and predominant winds during the collapse of the the PM53 fraction, except 3.23% in sample 13) inductively coupled plasma-atomic emission WTC towers and surrounding buildings. and was therefore not feasible to study. The spectrometry (ICP-AES). The analytical Size fractionation of bulk samples. Bulk PM2,5 fraction, however, was present in suffi­ results will contribute to the understanding of samples of the seven dust samples described cient amounts (2-29-^.06% ot PM53 fraction) the composition and possible mechanisms of above were sieved with a 53-pm diameter mesh to study for potential respiratory health effects. toxicip' of PM; 5 derived from the destruction screen (USA Standard Testing Sieves; Fisher The sum of the size fraction percentages does of the WTC. Scientific, Pittsburgh, PA) on a shaker not total 100% of the original PM53 fraction Detailed experimental findings of these (Portable Sieve Shaker; Tyler Industrial because of sample loss during fractionation. studies are available in a U.S. EPA report Products, Mentor, OH). We processed the After overnight desiccation, filter weights were (2002a). sieved material (PM53) in an apparatus determined using an electrobalance (Model designed to isolate different PM fractions C-.30; Thermo Cahn, Madison, WT). A total Materials and Methods (Figure 2). The PM53 fraction wtis aerosolized quantity of about 50 mg from each site, col­ Collection of World Trade Center PM samples. through a 10-pm aerodynamic diameter cut lected on 1-3 filters per site, wa,s used in the Using a paper scoop, we sampled several out­ Wedding inlet (Anderson Instrument Co., study (Table 1). Mechanical scraping did not door locations a.s well as one indoor location, Fultonville, NY) to remove particles in the efficiently remove the PM2.5 from the filters, so all of which appeared undisturbed since the 10-53 pm range and isolate the PM|o fraction. it was necessary' to isolate the PM2 5 using an collapse of the towers, as judged by the pres­ The PMio fraction was then passed through a aqueous extraction procedure. ence of a smooth uniform layer of dust and 2.5-pm cut cyclone (BGI, Inc., Waltham, MA) Extraction of PM2,} from Teflon filters. the absence of indicators of recent human to remove the coarse fraction. The PM2.5 frac­ Filters containing the PMz.s fraction were activity. All samples were collected within a tion was collected on Teflon filters (Zefluor extracted using a modification of a method by half-mile of Ground Zero and labeled with Supported PTFE, 2-pm pore size, 47-mm Biran and co-workers (1996). Filters from each of the seven individual collection sites were extracted into distilled w'ater (Gibco JWi Invitrogen, Carlsbad, CA) in the ratio of 0.5 mL/mg sample (24.96-27.14 mL water).

% I HucsonJ © ___ V s tn ••ij* 7^ i 51 3

% al Q J3J

A X‘9' Figure 2. Apparatus used to separate bulk samples Sf A 300 feet of WTC PM into different size fractions. Sieved WTC dust (PM53) was aerosolized in the resuspen­ sion chamber (A), then passed through a lO-pm cut Figure 1. WTC dust samples were collected by New York University scientists from 13 sites on inlet (S) and a 2.5-pm cut cyclone |C). PM25 were 12 September 2001 (numbers) and from 6 sites on 13 September 2001 (letters). Collection sites are shown collected on Teflon filters (0) and pulled through by only for samples reported in this article. Map reference: U.S. Census Bureau (2002). a pump (£].

Environmental Health Perspectives • volume 1111 number 71 June 2003 973

CITY_21MC1OO_O121786O3

NYC-WTC_000338881

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338881Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →