NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 9 pages

WTC World Trade Center health/PM2.5 monograph

Machine-extracted title · confidence 50%

EPA/HMH analyses on PM2.5 toxicity relevant to WTC environmental health effects.

NYC-WTC_000418055–000418063
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mini-Monograph i Chemical analysis of WTC PM; 5

the composition of these samples with other numbers (1-13) oir 12 September 2001, and diameter; Pall Gelmair Sciences, Port well-studied PM2.5 reference samples. Solid letters (A-E) on 13 September 2001. After Washington, NY). Ten to 40 filters were samples of WTC and reference PM2.5 wore examination of the available inventory of used in the size fractionation of each WTC analyzed by scanning electron microscopy samples, we selected seven locations (8, 11, sample. Roughly half the sample was in the (SEM), X-ray diffraction (XRD), X-ray fluo­ 13, B, C, E, and F) to assess toxicity of sam- PM53-sieved fraction. About 80-89% of the rescence (XRF), carbon fraction analysis, and ple.s from different geographical location.s a.s PM53 fraction wa.s in the 10- to 53-pm size neutron activation analysis (NAA). Analyses well as overall toxicity of a pooled sample range, which is too large to use in respiratory were also carried out on water-extracted or from these locations (Figure 1). The locations toxicologjr studies, as deposition of particles 1 M hydrochloric acid-extracted suspensions were selected to represent a distribution sur­ > 5 pm is minimal in small laboratory animals of WTC and reference PM2.5, including rounding Ground Zero, with more collection (Raabe et al. 1988). The amount of the 2.5- to pH, endotoxin, and inductively coupled sites in the east reflecting the direction of the 10-pm fraction was very small (0.04-1.14% of plasma-mass spectrometry (ICP-MS) and predominant winds during the collapse of the the PM53 fraction, except 3.23% in sample 13) inductively coupled plasma-atomic emission WTG towers and surrounding buildings. and was therefore not feasible to study. The spectrometry (ICP-AES). The analytical Size fractionation of bulk samples. Bulk PY2.5 fraction, however, was present in suffi­ results will contribute to the understanding of samples of the seven dust samples described cient amounts (2.29-4.06% of PM53 fraction) the composition and possible mechanisms of above were sieved with a 53-pm diameter mesh to study for potential respiratory health effects. toxicity of PM2 5 derived froiir the destructioir screeir (USA Standard Testing Sieves; Fisher The sum of tire size fraction percentages does of the WTC. Scientific, Pittsburgh, PA) on a shaker not total 100% of the original PM53 fraction Detailed experimental findings of these (Portable Sieve Shaker; Tyler Industrial because of sample loss during fractionation. studies are available in a U.S. EPA report Products, Mentor, OH). We processed the After overnight desiccation, filter weights were (2002a). sieved material (PM53) in an apparatus determined using an electrobalance (Model designed to isolate different PM fraction.s C-30; Thermo Cahn, Madison, WT). A total Materials and Methods (Figure 2). The PM53 fraction was aerosolized quantity of about 50 mg from each site, col­ Collection of World Trade Center PM samples. through a 10-pm aerodynamic diameter cut lected on 1-3 filters per site, was used in the Using a paper scoop, we sampled several out­ Wedding inlet (Anderson Instrument Co., study (Table 1). Mechanical scraping did not door locations as well as one indoor location, Fultonville, NY) to remove particles in the efficiently remove the PM2.5 from the filters, so all of which appeared undisturbed since the 10-53 pm range and isolate the PMjq fraction. it was necessary to isolate the PM2.5 using an collapse of the towers, as judged by the pres­ The PM 10 fraction was then passed through a aqueous extraction procedure. ence of a smooth uniform layer of dust and 2.5-pm cut cyclone (BGI, Inc., Waltham, MA) Extraction ofPM2,^fr0m Teflon filters. the absence of indicators of recent human to remove the coarse fraction. The PM 2 2 frac­ Filters containing the PM2.5 fraction were activity. All samples were collected within a tion was collected on Teflon filters (Zefluor extracted using a modification of a method by half-mile of Ground Zero and labeled with Supported PTFE, 2-pm pore size, 47-mm Biran and co-workers (1996). Filters from each of the seven individual colleccioir sices were extracted into distilled water (Gibco PII ..................... ’ T % Invitrogen, Carlsbad, CA) in the ratio of 0.5 mE/mg sample (24.96-27.14 mE water).

Illi iil IS 1 Hudson: ?/ River c 7

^*1 JI D

E 33]

F

B 1 iii lii Figure 2. Apparatus used to separate bulk samples of WTC PM into different size fractions. Sieved ........ 300 feet WTC dust (PM53) was aerosolized in the resuspen­ sion chamber (A), then passed through a 10-pm cut Figure 1. WTC dust samples were collected by New York University scientists from 13 sites on inlet (S) and a 2.5-pm cut cyclone (C). PM25 were 12 September 2001 (numbers) and from 6 sites on 13 September 2001 (letters). Collection sites are shown collected on Teflon filters (0) and pulled through by only for samples reported in this article. Map reference: U.S. Census Bureau (2002). a pump (£).

Environmental Health Perspectives • volume 1111 number 7 I June 2003 973

CITY_21MC100_011068668

NYC-WTC_000418056

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418056Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →