NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 176 pages

Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mini-Monoqraph I McGee et al.

This volume of water was pipetted into a for chemical or physical analysis, or for use in PM wlili moderate toxicity, a crustal PM with 100-mL sterile plastic cup containing a toxicologic studies in mice (Gavett et al. 2002). low toxicity, and an emission source PM with 3 mm-thick Teflon ring on the bottom Sample usedfor inhalation exposure toxi­ high toxicity (Table 1). National Institute of designed to support the filter. Each filter was city testing. Because we needed to conduct a Standards and Technology (NIST) Standard wetted with 200 pL 70% ethanol on the pani­ nose-only inhalation exposure study to assess Reference Material (SRM) 1649a is an urban cle side, placed on top of the ring with the upper airway responses of test animals (Gavett ambient PM collected in the Washington, DC, particle side down, and a 6 mm-thick Teflon et al. 2003), a sufficient quantity of sample area in 1976—1977 over a 12-month period ring was placed on top of the filter. The cup was necessary for the exposure system (> 2 g). and represents a time-integrated sample (NIST with the filter was placed on ice and secured to As there was not cn[Ough PM2.5 or PM2.5-10 2001). This material was selected for compari­ an orbital shaJeer (Titer Plate Shaker; Lab-Line sample available to conduct this study, we son of toxicity of WTC PM2.5 with other typi­ Instruments, Melrose Park, IL). Samples were decided to use a PM53 sample (sieved but not cal urban air PM2.5 (albeit from an earlier era shaken at a low speed and sonicated for further fractionated) that was available in suf­ when leaded gasoline was still in use). This 30 min at a power setting of 30 (Sonic 300 ficient quantity to run through the inhalation material was collected as a total suspended par­ Dismembrator; Artek Systems Corp,, exposure system. The inhalation exposure sys­ ticulate (TSP) sample with a large amount of Farmingdale, NY)- Ten milliliters was pipet­ tem uses a 2.5-pm cut cyclone to remove coarse PM and larger nonrespirable PM. ted from each of the seven samples into a sin­ larger particles (Ledbetter et al. 1998), and Consequently, SRM 1649a wa,s size-fraction­ gle srerilized 150-mL Erlenmeyer flask on ice therefore measurement of the PM concentra­ ated and extracted using the procedures to make a pooled sample (WTCX). The pH tion in the exposure zone of the chamber rep­ described above for comparison with the WTC of the pooled and individual site samples was resents exposure to FM2 5, A sample of PM53 PM2 5 samples. determined immediately after extraction from location no. 3 (Figure 1; WTC3 in WIT J PM2,5 was also compared with a pre­ (Model 440; Coming Incorporated, Corning, Table 1), 0.3 miles east of Ground Zero (in viously size-separated PM2.5 fraction of a.di NY). Sonicated filters were desiccated before the predominant wind direction), was avail­ from Mt. St. Helens (MSH) in Washington reweighing to determine quantity extracted able in sufficient quantities for the nose-only State (Graham ct al. 1985). About halfofMSH (i.e., removed) from the filters (Tabic 1). inhalation exposure study. is crystalline in nature, primarily plagioclase, a Pooled and individual site samples were frozen Cont}-ol PM samples. To assess the relative series of compounds beginning with sodium at -80°C and lyophilized for 2 days at ~5.5°C toxicity of WTC PM2.5, pooled and individual aluminum silicate (NaAISi3O8) and ending and 140 mtorr (Virtis Company, Gardiner, site samples were compared with three other with calcium aluminum silicate (CaA12Si2O8j NY). Lyophilized samples were stored at 4°C well-characterized control PM2.5 samples. We that show continuous solid solution from albite and subsequently brought to room temperature chose samples representing an urban ambient to anorthite, with Ca.AI replacing NaSi as the series progresses. The remaining portion is Table 1. Description of samples used in study. amorphous (glass) and contains minor amounts Extracted of cristobalite (3%,) and quartz (< 1%). The Sample Collection Size Total weight weight (mg) PM2.5 fraction of MSH has low toxicity in rats code date Location, description fraction on filters % E.xtracted and mice (Hatch et al. 1984). WTC site samples Residual oil fly ash (ROFA) is a PM sam­ WTC8 12 Sept. 2001 Beekman St.: filters #9, #14 PM2.5 53.316 mp 46.70 ple with a high content of bioavailable transi­ 0.4 miles E of Ground Zero 87.6 tion metals including vanadium (V), nickel WTC11 12 Sept. 2001 55 Church St: filters #13, #14, #15 PM2.5 50.097 mg 29.79 (Ni), and iron. (Fe). Numerous studies have In front of Millennium Hilton Hotel 59.5 0.1 miles E of Ground Zero demonstrated that these metals are associated Church and Liberty Sts.: filters #4, #5 51.006 mg with lung injury in both healthy animals and W1C13 12 Sept. 2001 PM2.5 46.29 0.1 miles SE of Ground Zero 90.8 animal models of cardiopulmonary injury V7TCB 13 Sept. 2001 Trinity Pt. and Rector St: filter #4 PMz5 52.969 mg 42.31 (Dreher et al. 1997; Gavett ct al. 1999; From a car hood and windshield 79.9 Kodavanti et al. 1998). For this study, we 0.25 miles S of Ground Zero chose a sample of ROFA (no, 3; Kodavanti WTCC 13 Sept. 2001 Winter Garden Park: filters #4, #7 PMz.s 54.285 mg 47.67 et al, 1998) from a boiler system that is toxic, From a park bench facing the Hudson River 87.8 yet not as soluble in water as previous samples 0.2 miles WNW of Ground Zero of ROFA, and is therefore more comparable to WICE 13 Sept. 2001 Murray and Greenwich Sts.: filters #5, #6 PM2.5 49.919 mg 45 13 WTC PM samples, which arc not extremely From a window ledge 90.4 water soluble, ROFA sample no, 3 has an 0.25 miles NNE of Ground Zero MMAD of 2.665 pm, slightly larger than WTCF 13 Sept. 2001 Inside 120 Broadway: filters #2, #12 PM2.5 53.600 mg 38.73 other PM2,5 samples used in this study but still From a marble staircase with no footprints 72.3 0.25 miles SE of Ground Zero acceptable for toxicity tesriiig. Overview ofanalytical methods. zVnalytical WTC3 12 Sept. 2001 23 Park Row: ground sample in front of PM<53 21.521 g Not extracted; J&R Electronics (across City Hall Park| sieved size-separated chemistry of WTC. SRM 1649a, MSH, and 0.3 miles E of Ground Zero material during exposure ROFA PM2 5 samples entailed measurements Control PM samples of both solid samples and their liquid extracts. SRM 1976-1977 SRM 1643a PM25 47.984 rag® 39.33 Solid (including lyophilized) samples were 1649a (urban dust collected in Washington, DC) 82.0 characterized by SEM/energy dispersive X-ray MSH 1980 Mt. St Helens ash, Washington State, from PM2.5 >10g" Previously size- analysis (SEM/EDX), XRD, NAA, XRF, and Graham et al. (1985) separated ca rbon fraction analysis of the organic, elemen­ RO FA 1994 Residual oil fly ash, ROFA sample 3 from MMAD: >2g® Milled; not tal, and carbonate fractions (OC/EC/CC), Kodavantietal.(1998! 2.665 pm extracted Deionized water extracts were characterized by Abbreviations: E, east; NNE, north-northeast S, south; SE, southeast WWW, west-northwest. pH, endotoxin, and ion chromatography (IC) AA/eight available analysis. F.lcmcntal and sulfate (SO4) content

974 VOLUME 1111 NUMBER 7 I June 2003 • Environmental Health Perspectives

CITY_21MC1OO_O121786O4

NYC-WTC_000338882

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338882Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →