NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Lead-in-dust wipe sampling, Stuyvesant HS, Feb 2002

Machine-extracted title · confidence 48%

Lead dust wipe sampling report for Stuyvesant HS, February 2002.

NYC-WTC_000336528–000336530
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content after a cleanup is completed in the 5* floor hallway and room #635 floor surfaces. This cleanup was recommended by ATC in conjunction with laboratory results of lead dust wipes collected on February 6'\ 2002 where elevated levels of lead were detected in the dust wipes collected from the floor of 5”’ floor hallway and room #635.

ATC’s representative Mr. Herant Antonyan visited Stuyvesant HS (M477) located at 345 Chamber Street, New York, NY on February 7"’, 2002. Dust wipes to be analyzed for lead content were collected from the 5"’ floor hallway and room #535 floor surfaces after the cleanup is completed.

LEAD-TN-D UST SAMPLING

Lead-in-dust threshold levels Tire New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below;

For Floors; 40 pg/ft2

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number; 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a new glove was worn with each new sampling procedure, and care was taken to avoid contamination of the towelette and collection vial. Towelettes were then placed into 50ml plastic vials and immediately sealed. The chain of custody form was completed and documents the measurement of the area sampled.

Stuyvesanl HS ('M477J (Swrc February 8, 2002

CITY_21MC100_003072416 NYC-WTC_000336529

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000336529Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →