Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content after a lead-in-dust cleanup is completed in the cafeteria and H' floor lobby floor surfaces and auxiliary gymnasium windowsill surfaces. This cleanup was recommended by ATC in conjuction with laboratory results of lead dust wipes collected on January 2''“^, 2002 where elevated levels of lead were detected in the dust wipes collected from the floor of cafeteria and 1® floor lobby as well as the windowsill of the auxiliary gymnasium.

ATC’s representative Mr. Herant Antonyan visited Stuyvesant HS (M477) located at 345 Chamber Street, New York, NY on January 3’'', 2002. Dust wipes to be analyzed for lead content were collected from the cafeteria and 1” floor floor surfaces and the auxiliary gymnasium windowsill surfaces after the lead-in-dust cleanup is completed.

LEAD-IN-D UST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, pail 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly refeiTed to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 pg/tf For Floors: 40 pg/ft"

Sampling Methodology' ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory' Accreditation Program to perfonn lead and related analyses of environmental samples (Laboratory ID Number; 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The lead-in-dust samples were obtained by gently wiping a pre-measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a new glove was worn with each new sampling procedure, and care was taken to avoid contamination of the towelette and collection vial. Towelettes were then placed into 50ml plastic vials and immediately sealed. The chain of custody form was completed and documents the measurement of the area sampled.

Stuyvesant HS (M477) January 4, 2002 »6B0CI«'fS IMC

CITY_21MC100_003072401

NYC-WTC_000336522

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000336522Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →