Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect additional dust wipes to be analyzed for lead content in conjunction with
laboratory results of lead dust wipes collected on February 19"', 2002 where elevated
levels of lead were detected in the dust wipes collected from the floor of Auditorium and
classroom #311.
ATC’s representative Mr. Yiannis Efstathiou visited P.S. 234M located at 292 Greenwich
Street, New York, NY on February 20"’, 2002. Dust wipes to be analyzed for lead content
were collected from the Auditorium and classroom #311 floor and windowsill surfaces as
well as from other locations throughout the 2"" and 3'" floors indicated to ATC by NYC-
BOE and Parents Association consultant representatives on site.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Floors:' 40 pg/ft^
For Windowsills 250 pg/tf
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). Tlie laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
The lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new' glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial. Towelettes were then placed into
50ml plastic vials and immediately sealed. The chain of custody form was completed and
documents the measurement of the area sampled.