NYC 9/11 Public Portal Document
Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were
collected from areas throughoui the school building.
The purposed of the dust wipe sampling is to determine if dust in the school contains
lead.
ATC’s representative Ms. Mariana Medinets visited P.S. 234M located at 292 Greenwich
Street, New York, NY on November 29"', 2001. Dust wipes to be analyzed for lead
content were collected from various areas throughout the school building as specified by
the New York City Board of Education Environmental Health & Safety Unit and in
accordance with HUD protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection- Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has talcen place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Window wells: 400 pg/tf
For Windowsills: 250 pg/fV
For Floors: 40 pg/tf
Although the lead-in-dust samples collected at P.S. 234M were not collected in response to
lead abatement, the same thresholds are used since no other regulations or standards are
applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
Ttie lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial. Towelettes were then placed into