Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content after a lead-in-dust cleanup is
completed in the following location:
• Room #401 - floor surface
This cleanup was recommended by ATC in conjunction with laboratory results of lead dust
wipes collected on April 5“’, 2002 where elevated levels of lead was detected in the dust
wipe collected from the floor surface of room #401.
ATC’s representative Herant .Antonyan visited PS 89 M located at 201 Warren Street,
New York, NY on April 5"’, 2002. Dust wipes to be analyzed for lead content were
collected from the floor surface and windowsill of room #401 after the lead-in-dust
cleanup was completed.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Windowsills: 250 pg/h'
For Floors: 40 pg/ft"
For Exterior Concrete or Rough Surfaces: 800 pg/fV
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Accreditation Program to perform lead and related analyses of environmental samples
(Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental
Protection Agency analysis method number SW846-7420 and the National Institute of
Occupational Safety and Health method number 7082M.
The lead-in-dust samples were obtained by gently wiping a pre-measured surface area
with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; a
new glove was worn with each new sampling procedure, and care was taken to avoid
contamination of the towelette and collection vial. Towelettes were then placed into
50ml plastic vials and immediately sealed. The chain of custody form was completed and
documents the measurement of the area sampled.
PS89M
(SWTC
A6SOCI«r6« INC
April 8, 2002
CITY_21MC100_003108742
NYC-WTC_000274512