NYC 9/11 Public Portal Document

Waste Water

SciLab Overview | Asbestos Microscopy | Environmental Chemistry | Environmental Microbiology

Air filter samples tested for asbestos are collapsed with acetone, mounted on slides, partially ashed in a low temperature plasma, carbon-coated, mounted on copper specimen grids, and dissolved.

Prepared grids are examined by Analytical Transmission Electron Microscopy (TEM). TEM is used to count and characterize suspect asbestos fibers by morphology and internal structure, the latter by selected area electron diffraction, or (SAED). The microscopes are interfaced with Energy Dispersive X-ray (EDX) Spectrometers, which help to confirm chemical compositions of the fibers.

Water, dust and bulk samples are also analyzed by TEM. For such samples, vacuum filtration of aqueous suspensions derived from the samples is conducted prior to preparation of the filters. Quantitative matrix reduction (ashing and/or acid dissolution) is also necessary for most bulk building material samples.

TEM is very useful for confirming problematic samples (floor tiles, roofing, etc.) that actually contain many small or organically bound asbestos fibers which cannot be detected by PLM. It can also be used to quantify very low levels of asbestos (0.1 % by weight or less) on some types of bulk samples.

Micro Analytical Laboratories. Inc.'s PLM bulk sample analyses follow the EPA Test Method for Determination of Asbestos in Bulk Building Materials, 1993 (EPA/600/R-93/116). Samples are first examined with a stereobinocular microscope. Representative portions of the sample are mounted on slides with refractive index oils and analyzed with a Polarized Light Microscope (PLM).

If no asbestos is found in a sample, "ND" (None Detected) is reported. If asbestos is found in a sample, two kinds of information are reported in the "asbestos minerals" column of the PLM report. First, the area percentage of asbestos, as determined by visual estimation by PLM. Second, the types of asbestos found are indicated. Additional information about non-asbestos fibers and non-fibrous materials is also recorded.

Many samples consist of distinct materials or layers, which are analyzed separately. Asbestos results from each layer or material are reported individually.

CITY_21MC100_0 06763226

NYC-WTC_000332101

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000332101Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279330

First draft outlining TEM/PCM methods for asbestos identification and analysis.

Similar indexed content

Compare copies and versions →